{"id":23413,"date":"2026-02-04T09:04:51","date_gmt":"2026-02-04T09:04:51","guid":{"rendered":"https:\/\/www.kcsensor.com\/?p=23413"},"modified":"2026-02-04T09:04:53","modified_gmt":"2026-02-04T09:04:53","slug":"ultrasonic-level-monitoring-for-storage-basins","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/cs\/ultrasonic-level-monitoring-for-storage-basins\/","title":{"rendered":"KUS-M56 Ultrazvukov\u00fd sn\u00edma\u010d hladiny pro monitorov\u00e1n\u00ed hladiny v pr\u016fmyslov\u00fdch z\u00e1sobn\u00edch n\u00e1dr\u017e\u00edch"},"content":{"rendered":"<h3 class=\"wp-block-heading\"><strong>1. Pozad\u00ed projektu<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u016fmyslov\u00fd are\u00e1l v <strong>Mnichov, N\u011bmecko<\/strong>&nbsp;vy\u017eadovan\u00e9 nep\u0159etr\u017eit\u00e9 sledov\u00e1n\u00ed hladiny pro <strong>venkovn\u00ed pr\u016fmyslov\u00e1 skladovac\u00ed n\u00e1dr\u017e<\/strong>, kter\u00fd slou\u017e\u00ed k akumulaci procesn\u00ed vody a sb\u011bru de\u0161\u0165ov\u00e9 vody. Provozovatel\u00e9 pot\u0159ebovali m\u00edt p\u0159ehled o hladin\u00e1ch kapaliny v re\u00e1ln\u00e9m \u010dase, aby zabr\u00e1nili p\u0159ete\u010den\u00ed a zajistili spr\u00e1vn\u00e9 hospoda\u0159en\u00ed s vodou.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\">D\u0159\u00edve se hladiny kapalin kontrolovaly ru\u010dn\u011b, co\u017e bylo \u010dasov\u011b n\u00e1ro\u010dn\u00e9 a v p\u0159\u00edpad\u011b n\u00e1hl\u00e9ho p\u0159\u00edtoku neposkytovalo v\u010dasn\u00e9 informace. Aby se tento probl\u00e9m vy\u0159e\u0161il, <strong><a href=\"\/cs\/product\/kus-m56-series-ultrasonic-sensor\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ultrazvukov\u00fd sn\u00edma\u010d hladiny KUS-M56<\/a><\/strong>&nbsp;byl namontov\u00e1n na nosnou konzolu zav\u011b\u0161enou nad n\u00e1dr\u017e\u00ed, \u010d\u00edm\u017e zaji\u0161\u0165oval nep\u0159etr\u017eit\u00e9 bezkontaktn\u00ed sledov\u00e1n\u00ed hladiny.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"757e84\" data-has-transparency=\"false\" style=\"--dominant-color: #757e84;\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"627\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2-1024x627.webp\" alt=\"KUS-M56 \u2013 Sledov\u00e1n\u00ed hladiny v pr\u016fmyslov\u00fdch z\u00e1sobn\u00edch n\u00e1dr\u017e\u00edch (2)\" class=\"wp-image-23598 not-transparent\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2-1024x627.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2-300x184.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2-768x470.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2-600x367.webp 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-2.webp 1242w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Probl\u00e9my p\u0159i m\u011b\u0159en\u00ed<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mezi hlavn\u00ed v\u00fdzvy spojen\u00e9 s touto aplikac\u00ed pat\u0159ily:<br>\u25cf Venkovn\u00ed prost\u0159ed\u00ed, kter\u00e9 vy\u017eaduje spolehliv\u00fd dlouhodob\u00fd provoz<br>\u25cf Pr\u016fmyslov\u00e1 n\u00e1dr\u017e s otev\u0159en\u00fdm vrchem, u n\u00ed\u017e se hladina kapaliny m\u011bn\u00ed v z\u00e1vislosti na sr\u00e1\u017ek\u00e1ch a provozn\u00edch podm\u00ednk\u00e1ch<br>\u25cf Omezen\u00fd instala\u010dn\u00ed prostor, co\u017e vy\u017eaduje kompaktn\u00ed konstrukci sn\u00edma\u010de<br>\u25cf P\u0159\u00edm\u00e1 integrace s PLC dan\u00e9ho za\u0159\u00edzen\u00ed pomoc\u00ed analogov\u00e9ho v\u00fdstupu 4\u201320 mA<br>\u25cf Jednoduch\u00e1 instalace a minim\u00e1ln\u00ed n\u00e1roky na \u00fadr\u017ebu pro person\u00e1l na m\u00edst\u011b<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. \u0158e\u0161en\u00ed<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sn\u00edma\u010d KUS-M56 m\u011b\u0159\u00ed vzd\u00e1lenost od \u010dela sn\u00edma\u010de k hladin\u011b kapaliny a poskytuje pr\u016fb\u011b\u017en\u00e9 \u00fadaje o hladin\u011b. V tomto projektu je <strong>Analogov\u00fd v\u00fdstup 4\u201320 mA<\/strong>&nbsp;byl p\u0159ipojen p\u0159\u00edmo k PLC za \u00fa\u010delem monitorov\u00e1n\u00ed v re\u00e1ln\u00e9m \u010dase a signalizace alarm\u016f p\u0159i p\u0159ekro\u010den\u00ed horn\u00ed a doln\u00ed mezn\u00ed hodnoty.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>3.1 Konfigurace za\u0159\u00edzen\u00ed<\/strong><strong><\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ultrazvukov\u00fd senzor KUS-M56<\/strong><\/li>\n\n\n\n<li>Nosn\u00e1 konzola, upevn\u011bn\u00e1 nad pr\u016fmyslovou akumula\u010dn\u00ed n\u00e1dr\u017e\u00ed<\/li>\n\n\n\n<li>Nap\u00e1jec\u00ed zdroj 24 V DC<\/li>\n\n\n\n<li><strong>Analogov\u00fd v\u00fdstup 4\u201320 mA<\/strong>&nbsp;p\u0159ipojen\u00e9 k PLC<\/li>\n\n\n\n<li>LED displej pou\u017e\u00edvan\u00fd k m\u00edstn\u00ed kontrole<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>3.2 Hlavn\u00ed technick\u00e9 parametry<\/strong><strong><\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Parametr<\/strong><strong><\/strong><\/td><td><strong>Specifikace<\/strong><strong><\/strong><\/td><\/tr><tr><td>Rozsah m\u011b\u0159en\u00ed<\/td><td>A\u017e 6 m<\/td><\/tr><tr><td>P\u0159esnost m\u011b\u0159en\u00ed<\/td><td>0.5% \u2013 1.0%<\/td><\/tr><tr><td>\u00dahel vyza\u0159ov\u00e1n\u00ed<\/td><td>20\u00b0<\/td><\/tr><tr><td>Pou\u017eit\u00fd v\u00fdstup<\/td><td>4\u201320 mA<\/td><\/tr><tr><td>Zobrazit<\/td><td>Integrovan\u00e1 LED dioda<\/td><\/tr><tr><td>Okoln\u00ed teplota<\/td><td>-20 a\u017e +60 \u2103<\/td><\/tr><tr><td>T\u0159\u00edda ochrany<\/td><td>IP66<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>3.3 Proces implementace<\/strong><strong><\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Instalace<\/strong><br>P\u0159 <strong><a href=\"\/cs\/product\/kus-m56-series-ultrasonic-sensor\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ultrazvukov\u00fd sn\u00edma\u010d hladiny KUS-M56<\/a><\/strong> bylo namontov\u00e1no nad pr\u016fmyslovou akumula\u010dn\u00ed n\u00e1dr\u017e\u00ed pomoc\u00ed nosn\u00e9 konzoly, \u010d\u00edm\u017e byla zaji\u0161t\u011bna voln\u00e1 dr\u00e1ha k hladin\u011b kapaliny. Instalace byla dokon\u010dena bez naru\u0161en\u00ed provozu za\u0159\u00edzen\u00ed.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-dbc85646 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img data-dominant-color=\"5c7b72\" data-has-transparency=\"false\" decoding=\"async\" width=\"654\" height=\"442\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KUS-M56-series-ultrasonic-sensor-2.webp\" alt=\"Ultrazvukov\u00fd senzor \u0159ady KUS-M56 2\" class=\"wp-image-22871 not-transparent\" style=\"--dominant-color: #5c7b72; aspect-ratio:16\/9;object-fit:cover;width:auto;height:470px\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KUS-M56-series-ultrasonic-sensor-2.webp 654w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KUS-M56-series-ultrasonic-sensor-2-300x203.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KUS-M56-series-ultrasonic-sensor-2-600x406.webp 600w\" sizes=\"(max-width: 654px) 100vw, 654px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"666867\" data-has-transparency=\"false\" decoding=\"async\" width=\"473\" height=\"632\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-1.webp\" alt=\"KUS-M56 \u2013 Sledov\u00e1n\u00ed hladiny v pr\u016fmyslov\u00fdch z\u00e1sobn\u00edch n\u00e1dr\u017e\u00edch (1)\" class=\"wp-image-23597 not-transparent\" style=\"--dominant-color: #666867; aspect-ratio:1;object-fit:cover\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-1.webp 473w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/02\/KUS-M56-Industrial-Storage-Basin-Level-Monitoring-1-225x300.webp 225w\" sizes=\"(max-width: 473px) 100vw, 473px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Provoz<\/strong><br>Senzor nep\u0159etr\u017eit\u011b sleduje hladinu v n\u00e1dr\u017ei a vys\u00edl\u00e1 sign\u00e1l 4\u201320 mA do PLC. PLC p\u0159ev\u00e1d\u00ed tento sign\u00e1l na procentu\u00e1ln\u00ed hodnotu hladiny a p\u0159i dosa\u017een\u00ed prahov\u00fdch hodnot spou\u0161t\u00ed alarmy pro vysokou a n\u00edzkou hladinu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00dadr\u017eba<\/strong><br>Bezkontaktn\u00ed provoz eliminuje mechanick\u00e9 opot\u0159eben\u00ed. Pravideln\u00e1 \u00fadr\u017eba se omezuje na vizu\u00e1ln\u00ed prohl\u00eddky a z\u00e1kladn\u00ed kontroly funk\u010dnosti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. V\u00fdsledky a v\u00fdkonnost projektu<\/strong><strong><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Ukazatel v\u00fdkonnosti<\/strong><strong><\/strong><\/td><td><strong>V\u00fdsledek<\/strong><strong><\/strong><\/td><\/tr><tr><td>Stabilita m\u011b\u0159en\u00ed<\/td><td>Stabiln\u00ed a opakovateln\u00e9<\/td><\/tr><tr><td>Dostupnost syst\u00e9mu<\/td><td>&gt;99%<\/td><\/tr><tr><td>\u010cetnost \u00fadr\u017eby<\/td><td>Pouze vizu\u00e1ln\u00ed kontrola<\/td><\/tr><tr><td>Doba instalace<\/td><td>~20\u201330 minut na umyvadlo<\/td><\/tr><tr><td>Sn\u00ed\u017een\u00ed po\u010dtu ru\u010dn\u00edch kontrol<\/td><td>V\u00fdznamn\u00fd<\/td><\/tr><tr><td>Zp\u011btn\u00e1 vazba od oper\u00e1tor\u016f<\/td><td>V po\u0159\u00e1dku; LED displej je \u010diteln\u00fd, sign\u00e1l PLC je spolehliv\u00fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Z\u00e1v\u011br<\/strong><\/h3>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\">P\u0159 <strong><a href=\"\/cs\/product\/kus-m56-series-ultrasonic-sensor\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ultrazvukov\u00fd senzor KUS-M56<\/a><\/strong> poskytuje <strong>kompaktn\u00ed, spolehliv\u00e9 a snadno instalovateln\u00e9 \u0159e\u0161en\u00ed<\/strong>\u00a0pro monitorov\u00e1n\u00ed hladiny v pr\u016fmyslov\u00fdch venkovn\u00edch z\u00e1sobn\u00edc\u00edch. Nep\u0159etr\u017eit\u00e9 bezkontaktn\u00ed m\u011b\u0159en\u00ed a integrace s PLC umo\u017e\u0148uj\u00ed obsluze sledovat hladiny kapalin v re\u00e1ln\u00e9m \u010dase, omezit ru\u010dn\u00ed kontroly a zlep\u0161it \u0159\u00edzen\u00ed provozu. Toto \u0159e\u0161en\u00ed je vhodn\u00e9 pro <strong><strong>pr\u016fmyslov\u00e9 z\u00e1sobn\u00ed n\u00e1dr\u017ee, n\u00e1dr\u017ee na procesn\u00ed vodu, n\u00e1dr\u017ee na sb\u011br de\u0161\u0165ov\u00e9 vody a obecn\u00e9 aplikace pro skladov\u00e1n\u00ed kapalin<\/strong><\/strong>, kde jsou kl\u00ed\u010dov\u00fdmi po\u017eadavky stabiln\u00ed monitorov\u00e1n\u00ed hladiny a snadn\u00e1 integrace.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\">Chcete-li z\u00edskat dal\u0161\u00ed technick\u00e9 podrobnosti, sch\u00e9mata zapojen\u00ed nebo pokyny k v\u00fdb\u011bru modelu, klikn\u011bte pros\u00edm na <strong><a href=\"\/cs\/contact-us\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/contact-us\/\" rel=\"noreferrer noopener\">zde<\/a><\/strong> Chcete-li se dozv\u011bd\u011bt v\u00edce, obra\u0165te se na n\u00e1\u0161 technick\u00fd t\u00fdm.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>1. Project Background An industrial facility in Munich, Germany&nbsp;required continuous level monitoring for an outdoor industrial storage basin, used for process water storage and rainwater collection. Operators needed real-time visibility of liquid levels to prevent overflow and ensure proper water management. Previously, liquid levels were checked manually, which was time-consuming and did not provide timely [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":23601,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[294],"tags":[480],"class_list":["post-23413","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cases","tag-kus-m56"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/posts\/23413","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/comments?post=23413"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/posts\/23413\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/media\/23601"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/media?parent=23413"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/categories?post=23413"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/tags?post=23413"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}