{"id":19626,"date":"2025-05-29T06:50:56","date_gmt":"2025-05-29T06:50:56","guid":{"rendered":"https:\/\/www.kcsensor.com\/?post_type=product&#038;p=19626"},"modified":"2026-02-06T08:44:50","modified_gmt":"2026-02-06T08:44:50","slug":"kld701-guided-wave-radar-level-meter","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/cs\/product\/kld701-guided-wave-radar-level-meter\/","title":{"rendered":"KLD701 Radarov\u00fd hladinom\u011br s vedenou vlnou pro kapaliny, pevn\u00e9 l\u00e1tky a pr\u00e1\u0161ky"},"content":{"rendered":"<h3><strong>Z\u00e1sada:<\/strong><\/h3>\n<p>Vysokofrekven\u010dn\u00ed mikrovlnn\u00e9 impulsy vys\u00edlan\u00e9 hladinom\u011brem s vedenou vlnou KLD701 se \u0161\u00ed\u0159\u00ed pod\u00e9l detek\u010dn\u00edho prvku (ocelov\u00e9ho lana nebo ocelov\u00e9 ty\u010de). P\u0159i setk\u00e1n\u00ed s m\u011b\u0159en\u00fdm m\u00e9diem doch\u00e1z\u00ed v d\u016fsledku n\u00e1hl\u00e9 zm\u011bny dielektrick\u00e9 konstanty m\u00e9dia k odrazu a \u010d\u00e1st energie impulsu se odr\u00e1\u017e\u00ed zp\u011bt. Vzd\u00e1lenost, na kterou se vys\u00edlan\u00fd a odra\u017een\u00fd impuls \u0161\u00ed\u0159\u00ed, je \u00fam\u011brn\u00e1 \u010dasov\u00e9mu intervalu m\u011b\u0159en\u00e9ho m\u00e9dia.<\/p>\n<h3><strong>Vlastnosti:<\/strong><\/h3>\n<p>D\u00edky pokro\u010dil\u00e9mu mikroprocesoru a jedine\u010dn\u00e9 technologii zpracov\u00e1n\u00ed odra\u017een\u00fdch sign\u00e1l\u016f lze radarov\u00fd hladinom\u011br s veden\u00fdmi vlnami KLD701 pou\u017e\u00edvat v nejr\u016fzn\u011bj\u0161\u00edch n\u00e1ro\u010dn\u00fdch podm\u00ednk\u00e1ch. D\u00edky typu procesn\u00edch p\u0159\u00edpojek a detek\u010dn\u00edch komponent je radarov\u00fd hladinom\u011br s veden\u00fdmi vlnami KLD701 vhodn\u00fd pro nejr\u016fzn\u011bj\u0161\u00ed n\u00e1ro\u010dn\u00e9 podm\u00ednky a aplikace. Nap\u0159\u00edklad: m\u00e9dia s vysokou teplotou, vysok\u00fdm tlakem a n\u00edzkou dielektrickou konstantou.<br \/>\nImpulzn\u00ed hladinom\u011bry s veden\u00fdmi vlnami vyza\u0159uj\u00ed velmi n\u00edzk\u00fd v\u00fdkon, lze je instalovat do nejr\u016fzn\u011bj\u0161\u00edch kovov\u00fdch i nekovov\u00fdch n\u00e1dob a nep\u0159edstavuj\u00ed \u017e\u00e1dn\u00e9 nebezpe\u010d\u00ed pro \u010dlov\u011bka ani \u017eivotn\u00ed prost\u0159ed\u00ed.<\/p>\n<h3><strong>Rozsah m\u011b\u0159en\u00ed<\/strong>\uff1a<\/h3>\n<p>Vysv\u011btlen\u00ed:<br \/>\nH\u2014 Rozsah m\u011b\u0159en\u00ed<br \/>\nL \u2013 Vzd\u00e1lenost mezi pr\u00e1zdn\u00fdmi m\u00edsty<br \/>\nB \u2013 Horn\u00ed okraj rolety<br \/>\nE \u2013 Minim\u00e1ln\u00ed vzd\u00e1lenost sondy od st\u011bny n\u00e1dr\u017ee<br \/>\nSlep\u00e1 z\u00f3na je minim\u00e1ln\u00ed vzd\u00e1lenost mezi horn\u00edm okrajem nejvy\u0161\u0161\u00edho povrchu materi\u00e1lu a referen\u010dn\u00edm bodem m\u011b\u0159en\u00ed.<br \/>\nSpodn\u00ed \u010d\u00e1st rolety ozna\u010duje vzd\u00e1lenost v bl\u00edzkosti sam\u00e9ho spodku lanka, kterou nelze p\u0159esn\u011b zm\u011b\u0159it.<br \/>\nMezi horn\u00edm a doln\u00edm okrajem \u017ealuzie se m\u011b\u0159\u00ed efektivn\u00ed vzd\u00e1lenost \u017ealuzie.<\/p>\n<p><img data-dominant-color=\"e6e6e6\" data-has-transparency=\"false\" style=\"--dominant-color: #e6e6e6;\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-19639 size-full not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/05\/KLD700-Measuring-range.webp\" alt=\"KLD701 Radarov\u00fd hladinom\u011br s veden\u00fdmi vlnami \u2013 Rozsah m\u011b\u0159en\u00ed\" width=\"479\" height=\"660\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/05\/KLD700-Measuring-range.webp 479w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/05\/KLD700-Measuring-range-218x300.webp 218w\" sizes=\"(max-width: 479px) 100vw, 479px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Vysokofrekven\u010dn\u00ed mikrovlnn\u00e9 impulsy vys\u00edlan\u00e9 hladinom\u011brem s vedenou vlnou KLD701 se \u0161\u00ed\u0159\u00ed pod\u00e9l detek\u010dn\u00edho prvku (ocelov\u00e9ho lana nebo ocelov\u00e9 ty\u010de). P\u0159i setk\u00e1n\u00ed s m\u011b\u0159en\u00fdm m\u00e9diem doch\u00e1z\u00ed v d\u016fsledku n\u00e1hl\u00e9 zm\u011bny dielektrick\u00e9 konstanty m\u00e9dia k odrazu a \u010d\u00e1st energie impulsu se odr\u00e1\u017e\u00ed zp\u011bt. Vzd\u00e1lenost, na kterou se vys\u00edlan\u00fd a odra\u017een\u00fd impuls \u0161\u00ed\u0159\u00ed, je \u00fam\u011brn\u00e1 \u010dasov\u00e9mu intervalu m\u011b\u0159en\u00e9ho m\u00e9dia.<\/p>","protected":false},"featured_media":19627,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"[table id=141 \/]","youtube_video":"","youtube_video_2":"","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"The product demonstration video is under preparation and will be released shortly.","product_3d_model":"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/12\/KLD701.glb","document":19632,"file_name_1":"KLD700 Series Guided Wave Radar Level Meter Datasheet_v1.2.pdf","3d_document":21902,"file_name_2":"KLD701 Guided Wave Radar Level Meter 3D file.zip","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":23720,"case1_title":"Chemical Storage Tank Monitoring","case1_link":"https:\/\/www.kcsensor.com\/guided-wave-radar-level-meter-tank-monitoring\/","case2_image":0,"case2_title":"","case2_link":"","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[315,239],"product_tag":[380,240],"class_list":["post-19626","product","type-product","status-publish","has-post-thumbnail","product_cat-guided-wave-radar","product_cat-radar-level-sensor","product_tag-guided-wave-radar","product_tag-radar-level-sensor","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product\/19626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/comments?post=19626"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product\/19626\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/media\/19627"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/media?parent=19626"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product_brand?post=19626"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product_cat?post=19626"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/cs\/wp-json\/wp\/v2\/product_tag?post=19626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}