{"id":18376,"date":"2025-02-25T07:43:38","date_gmt":"2025-02-25T07:43:38","guid":{"rendered":"https:\/\/kcsensor.com\/?post_type=product&#038;p=18376"},"modified":"2026-02-10T06:19:09","modified_gmt":"2026-02-10T06:19:09","slug":"kdf1100-wall-mounted-ultrasonic-doppler-flow-meter","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/de\/product\/kdf1100-wall-mounted-ultrasonic-doppler-flow-meter\/","title":{"rendered":"KDF1100 Wandmontierter Ultraschall-Doppler-Durchflussmesser"},"content":{"rendered":"<h3><strong><b>1.<\/b><\/strong><strong><b>Einf\u00fchrung<\/b><\/strong><\/h3>\n<p>Der Ultraschall-Doppler-Durchflussmesser ist ein Host, der die Durchflussgeschwindigkeit, den Wasserstand und die Temperatur des Ultraschall-Doppler-Durchflussmessers \u00fcber RS485 erfasst und verschiedene Kanalparameter entsprechend der tats\u00e4chlichen Situation vor Ort eingibt. Die Durchflussfl\u00e4che S (m\u00b2) wird anhand der Kanalparameter und des erfassten Wasserstands H (m) berechnet; die Momentan-Durchflussmenge (Q = V * S) ergibt sich aus der Multiplikation der Durchflussfl\u00e4che mit der Str\u00f6mungsgeschwindigkeit V (m\/s), und die kumulierte Durchflussmenge wird durch Multiplikation der Durchflussmenge mit der kumulierten Zeit ermittelt.<\/p>\n<p>Daraus l\u00e4sst sich ableiten: Q = V * S<\/p>\n<p>Momentaner Durchfluss * Zeitdifferenz = kumulierter Durchfluss<\/p>\n<h3><strong><b>2. Abmessungen<\/b><\/strong><\/h3>\n<h4><strong><b>2.1 Produktbild<\/b><\/strong><\/h4>\n<p><img data-dominant-color=\"75afb6\" data-has-transparency=\"false\" style=\"--dominant-color: #75afb6;\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-18381 size-medium not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Ultrasonic-Doppler-flowmeter-host-physical-picture-288x300.webp\" alt=\"KDF1100 Wandmontierter Ultraschall-Doppler-Durchflussmesser (Host) \u2013 Produktfoto\" width=\"288\" height=\"300\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Ultrasonic-Doppler-flowmeter-host-physical-picture-288x300.webp 288w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Ultrasonic-Doppler-flowmeter-host-physical-picture-png.webp 522w\" sizes=\"(max-width: 288px) 100vw, 288px\" \/> <img data-dominant-color=\"cfcec9\" data-has-transparency=\"false\" style=\"--dominant-color: #cfcec9;\" decoding=\"async\" class=\"alignnone wp-image-18380 size-medium not-transparent\" src=\"https:\/\/kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Physical-picture-of-the-sensor-including-all-accessories-300x285.webp\" alt=\"KDF1100 Wandmontierter Ultraschall-Doppler-Durchflussmesser \u2013 Abbildung des Sensors (einschlie\u00dflich s\u00e4mtlichem Zubeh\u00f6r)\" width=\"300\" height=\"285\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Physical-picture-of-the-sensor-including-all-accessories-300x285.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-Physical-picture-of-the-sensor-including-all-accessories-png.webp 523w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h4><strong><b>2.2 Strukturgr\u00f6\u00dfe<\/b><\/strong><\/h4>\n<p>Die Abmessungen ohne Montagezubeh\u00f6r betragen Breite \u00d7 H\u00f6he \u00d7 Tiefe = 200 \u00d7 215 \u00d7 90 m.<\/p>\n<p><img data-dominant-color=\"eeeeef\" data-has-transparency=\"false\" style=\"--dominant-color: #eeeeef;\" decoding=\"async\" class=\"alignnone wp-image-18379 size-full not-transparent\" src=\"https:\/\/kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-dimensions-png.webp\" alt=\"Abmessungen des wandmontierten Ultraschall-Doppler-Durchflussmessers KDF1100\" width=\"733\" height=\"814\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-dimensions-png.webp 733w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-dimensions-270x300.webp 270w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/02\/KDF1100-dimensions-600x666.webp 600w\" sizes=\"(max-width: 733px) 100vw, 733px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Ultraschall-Doppler-Durchflussmesser nutzen Schallwellen zur Messung der Str\u00f6mungsgeschwindigkeit von Fl\u00fcssigkeiten in Rohrleitungen. Diese Messger\u00e4te eignen sich besonders f\u00fcr Anwendungen mit Abwasser, Schlamm, Schlammbr\u00fche und bel\u00fcfteten Fl\u00fcssigkeiten und bieten eine effiziente L\u00f6sung f\u00fcr die genaue Durchflussmessung bei diesen schwer zu handhabenden Medien.<\/p>","protected":false},"featured_media":18409,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"[table id=123 \/]","youtube_video":"","youtube_video_2":"https:\/\/youtu.be\/iNT11kbv7i0","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"KDF1100 Wall-Mounted Ultrasonic Doppler Flow Meter | Installation & How to Use ?","product_3d_model":"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/12\/KDF1100.glb","document":23084,"file_name_1":"KDF1100 Wall-mounted Ultrasonic Doppler Flow Meter_V2.2.pdf","3d_document":21884,"file_name_2":"KDF1100 Wall-mounted Ultrasonic Doppler Flow Meter 3D file.zip","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":23675,"case1_title":"Wastewater Open Channel Monitoring","case1_link":"https:\/\/www.kcsensor.com\/doppler-flow-meter-for-wastewater-channels\/","case2_image":23674,"case2_title":"River Flow Measurement","case2_link":"https:\/\/www.kcsensor.com\/handheld-dopple-flow-meter-river-flow-monitoring\/","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[219],"product_tag":[324],"class_list":["post-18376","product","type-product","status-publish","has-post-thumbnail","product_cat-ultrasonic-flow-meter","product_tag-kdf1100-wall-mounted-ultrasonic-doppler-flow-meter","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product\/18376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/comments?post=18376"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product\/18376\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/media\/18409"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/media?parent=18376"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product_brand?post=18376"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product_cat?post=18376"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/de\/wp-json\/wp\/v2\/product_tag?post=18376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}