{"id":21365,"date":"2026-07-02T10:19:05","date_gmt":"2026-07-02T10:19:05","guid":{"rendered":"https:\/\/www.kcsensor.com\/?p=21365"},"modified":"2026-07-02T10:19:07","modified_gmt":"2026-07-02T10:19:07","slug":"china-kacise-ultrasonic-sensor-troubleshooting","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/es\/china-kacise-ultrasonic-sensor-troubleshooting\/","title":{"rendered":"Soluci\u00f3n de problemas del sensor ultras\u00f3nico KACISE de China"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"\/es\/category\/ultrasonic-sensor\/\" data-type=\"category\" data-id=\"114\" target=\"_blank\" rel=\"noreferrer noopener\">Sensor ultras\u00f3nico<\/a> son indispensables en diversas industrias, desde la automatizaci\u00f3n y la rob\u00f3tica hasta la medici\u00f3n de nivel y la detecci\u00f3n de objetos. Su capacidad para proporcionar mediciones precisas de distancia utilizando ondas sonoras les hace herramientas fiables. Sin embargo, como cualquier tecnolog\u00eda, los sensores ultras\u00f3nicos pueden encontrar problemas que afectan su precisi\u00f3n y funcionalidad. Comprender c\u00f3mo realizar la soluci\u00f3n de problemas de sensores ultras\u00f3nicos es crucial para mantener la fiabilidad del sistema y evitar costosos tiempos de inactividad.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Soluci\u00f3n de problemas de sensores ultras\u00f3nicos \u2014 Anormalidades de puerto serie<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1 Primero, comprueba si <a href=\"\/es\/category\/ultrasonic-sensor\/\" target=\"_blank\" data-type=\"category\" data-id=\"114\" rel=\"noreferrer noopener\">Sensor ultras\u00f3nico<\/a> El cableado es correcto y firmemente conectado. Luego comprueba el voltaje en ambos extremos del sensor.<br>Los sensores RS485 de baja potencia no pueden funcionar debajo <strong>3.3 V<\/strong>, y los sensores de salida actuales\/voltaje (modelos de potencia no baja) no pueden funcionar debajo <strong>10 V<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 Si el voltaje de alimentaci\u00f3n es normal, compruebe la corriente que fluye a trav\u00e9s del sensor. Conectar un par\u00e1metro en serie entre el sensor y la fuente de alimentaci\u00f3n (Steps: conectar el terminal positivo de la fuente de alimentaci\u00f3n al par\u00e1metro positivo, el par\u00e1metro negativo al sensor positivo, y el sensor negativo a la fuente de alimentaci\u00f3n negativa).<br>Observe el valor actual: para <strong>versiones de baja potencia (tipos RS485)<\/strong>, una corriente promedio debajo <strong>10 mA<\/strong> es normal; para <strong>versiones de potencia no baja (producci\u00f3n corriente o voltaje)<\/strong>, una corriente promedio debajo <strong>50 mA<\/strong> es normal.<br>Si la corriente es <strong>0<\/strong>, indica un fallo del circuito interno en el sensor, y debe ponerse en contacto con nosotros para mayor asistencia.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img data-dominant-color=\"f0eeef\" data-has-transparency=\"true\" fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"223\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2.webp\" alt=\"Diagrama de cableado de sensor ultras\u00f3nico\" class=\"wp-image-21367 has-transparency\" style=\"--dominant-color: #f0eeef; width:1063px;height:auto\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2.webp 500w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-300x134.webp 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u2462 <strong>Escuchen si el <strong><strong><a href=\"\/es\/category\/ultrasonic-sensor\/\" target=\"_blank\" data-type=\"category\" data-id=\"114\" rel=\"noreferrer noopener\">Sensor ultras\u00f3nico<\/a><\/strong><\/strong> produce un sonido \u201cticking\u201d.<\/strong><br>El sonido de garrapatas indica que el sensor est\u00e1 transmitiendo pulsos ultras\u00f3nicos.<br>Si el paso 2 es dif\u00edcil de realizar, puede escuchar este sonido para determinar si el sensor est\u00e1 operando.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2463 <strong>Si todos los pasos anteriores son normales pero el puerto serie todav\u00eda no funciona<\/strong>, el problema puede estar relacionado con la tasa de baudio o Modbus ID.<br>Puede modificar la tasa de baud en el software receptor. Los productos de serie ultras\u00f3nica Kaixing soportan hasta <strong>115200 bps<\/strong>.<br>Cambiar la tasa de baudio del m\u00e1s bajo al m\u00e1s alto, y <strong>despu\u00e9s de cada cambio<\/strong>, enviar un comando de transmisi\u00f3n:<strong>00 03 00 01 00 01 D4 1B<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si el dispositivo responde a una cierta tasa de baudio, indica que esta tasa de baudio es correcta y el sensor no es defectuoso.<br>A continuaci\u00f3n, puede modificar la tasa de baudio o ID Modbus al valor deseado.<br>Si el problema persiste, p\u00f3ngase en contacto con nosotros para obtener m\u00e1s asistencia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">El valor de medici\u00f3n del sensor ultras\u00f3nico se muestra siempre como 0 V (4 mA), 10 V (20 mA), o es incorrecto.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1 Realizar los pasos 1, 2, y 3 de la secci\u00f3n \u201cAnormalidades de Puerto serie\u201d primero.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 Compruebe si hay alguna obstrucci\u00f3n dentro del \u00e1ngulo del haz del sensor, si hay una salida de descarga, o si hay una superficie inclinada dentro del \u00e1ngulo del haz (la onda ultras\u00f3nica debe ser perpendicular al medio medido).<br>Tambi\u00e9n compruebe si cualquier materia extranjera se adjunta a la sonda del sensor (incluyendo gotitas de agua).<br>Cualquiera de estas condiciones puede afectar la medici\u00f3n normal del sensor ultras\u00f3nico.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img data-dominant-color=\"73767c\" data-has-transparency=\"true\" decoding=\"async\" width=\"740\" height=\"524\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-2.webp\" alt=\"Im\u00e1genes in situ del sensor ultras\u00f3nico\" class=\"wp-image-21368 has-transparency\" style=\"--dominant-color: #73767c; width:582px;height:auto\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-2.webp 740w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-2-300x212.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-2-600x425.webp 600w\" sizes=\"(max-width: 740px) 100vw, 740px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">3 Si el paso 2 no resuelve el problema, eliminar el <a href=\"\/es\/?elementor_library=all-blog-2\" target=\"_blank\" data-type=\"elementor_library\" data-id=\"13410\" rel=\"noreferrer noopener\">sensor ultras\u00f3nico<\/a> del entorno de trabajo.<br>Usar un <strong>RS485-a-USB convertidor<\/strong> para conectar el sensor a un ordenador, fijar el sensor en su lugar, apuntarlo a una pared, piso o techo, y encenderlo.<br>Primero realizar una prueba de s\u00ed mismo (cambiar la distancia) y observar si el sensor <strong>lecturas de distancia\/nivel<\/strong> son normales.<br>(Puede ponerse en contacto con nosotros para obtener el software Modbus Poll y el archivo MPB, o consultar el manual del producto para leer los resultados de medici\u00f3n de distancia\/nivel).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si las lecturas son normales, esto indica que el Sensor Ultras\u00f3nico no tiene ning\u00fan problema.<br>El problema puede deberse a condiciones de instalaci\u00f3n inadecuadas o interferencia electromagn\u00e9tica en el entorno de trabajo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Estado de trabajo Soluci\u00f3n de problemas<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1 Primero, pasos completos 1, 2, y 3 de la segunda parte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 La sonda ultras\u00f3nica y la carcasa deben intentar no ponerse directamente en contacto con el metal.<br>El contacto entre el sensor y los materiales met\u00e1licos afectar\u00e1 a la operaci\u00f3n normal de la sonda ultras\u00f3nica, y es necesario utilizar materiales como anillos de goma o cinta PTFE para \u201cislatar\u201d entre el sensor y el cuerpo del tanque de metal.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img data-dominant-color=\"7f907d\" data-has-transparency=\"true\" decoding=\"async\" width=\"957\" height=\"479\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-3.webp\" alt=\"Im\u00e1genes in situ de fallas de sensores ultras\u00f3nicos\" class=\"wp-image-21369 has-transparency\" style=\"--dominant-color: #7f907d; width:959px;height:auto\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-3.webp 957w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-3-300x150.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-3-768x384.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-3-600x300.webp 600w\" sizes=\"(max-width: 957px) 100vw, 957px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">3 El uso indebido del m\u00f3dulo de potencia tambi\u00e9n puede causar un funcionamiento anormal del sensor Ultras\u00f3nico.<br>Al utilizar un m\u00f3dulo de potencia AC-to-DC, es necesario se\u00f1alar que el negativo de potencia del sensor debe ser reducido al suelo.<br>Como se muestra en la figura, <strong>\u2013V (PIN4)<\/strong> debe reducirse <strong>GND (PIN3)<\/strong>.<br>Las razones son las siguientes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Establecer un punto de referencia estable:<\/strong><br>Proporcionar una referencia de voltaje unificada (0 V) para la medici\u00f3n de se\u00f1al del sensor, evitando la distorsi\u00f3n de medici\u00f3n causada por puntos de referencia flotantes.<\/li>\n\n\n\n<li><strong>Represi\u00f3n y blindaje de interferencia:<\/strong><br>Proporcionar un camino para la descarga de ruido, y formar un recinto de blindaje a trav\u00e9s de la puesta en tierra de la vivienda, suprimiendo efectivamente la interferencia electromagn\u00e9tica.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"506c5d\" data-has-transparency=\"true\" style=\"--dominant-color: #506c5d;\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"606\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4-1024x606.webp\" alt=\"DC to AC Power Supply\" class=\"wp-image-21370 has-transparency\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4-1024x606.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4-300x177.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4-768x454.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4-600x355.webp 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/11\/Troubleshooting-Guide-V0.2-4.webp 1351w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Despu\u00e9s de verificar los pasos anteriores, si sigue siendo anormal, p\u00f3ngase en contacto con nosotros.<br>El equipo t\u00e9cnico realizar\u00e1 operaciones remotas; por favor, coopere seg\u00fan lo que el equipo t\u00e9cnico diga.<br>Si el problema no puede resolverse, el equipo t\u00e9cnico propone devolver el producto a la f\u00e1brica.<br>En ese momento, las ventas de contacto para el manejo de seguimiento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Ultrasonic Sensor are indispensable in various industries\u2014from automation and robotics to level measurement and object detection. Their ability to provide accurate distance measurements using sound waves makes them reliable tools. However, like any technology, ultrasonic sensors can encounter issues that affect their accuracy and functionality. Understanding how to perform ultrasonic sensor troubleshooting is crucial to [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":21689,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[395,114],"tags":[],"class_list":["post-21365","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-faq","category-ultrasonic-sensor"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/posts\/21365","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/comments?post=21365"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/posts\/21365\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media\/21689"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media?parent=21365"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/categories?post=21365"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/tags?post=21365"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}