{"id":1251,"date":"2021-03-23T15:26:07","date_gmt":"2021-03-23T15:26:07","guid":{"rendered":"https:\/\/kcsensor.com\/?post_type=product&#038;p=1251"},"modified":"2025-04-09T08:05:04","modified_gmt":"2025-04-09T08:05:04","slug":"online-total-cadmium-analyzer-ktg600","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/es\/product\/online-total-cadmium-analyzer-ktg600\/","title":{"rendered":"Analizador de cadmio total en l\u00ednea KTG600"},"content":{"rendered":"<h3><a name=\"_Toc66953355\"><\/a><strong>Especificaciones t\u00e9cnicas<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"146\">Modelo<\/td>\n<td width=\"391\">KTG600<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Factor de seguimiento<\/td>\n<td width=\"391\">Total de cadmio<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">M\u00e9todo<\/td>\n<td width=\"391\">Reactivo de cadmio Espectrofot\u00f3metro<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Gama<\/td>\n<td width=\"391\">(0.004 a 10) mg\/L expandible<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Unidad de visualizaci\u00f3n<\/td>\n<td width=\"391\">Pantalla de matriz de puntos 12232, pantalla t\u00e1ctil LCD de 7 pulgadas con doble visualizaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Modo de medici\u00f3n<\/td>\n<td width=\"391\">Medici\u00f3n manual, medici\u00f3n continua, peri\u00f3dica<\/p>\n<p>medici\u00f3n, medici\u00f3n de puntos fijos, medici\u00f3n autom\u00e1tica de calibraci\u00f3n, verificaci\u00f3n de soluciones est\u00e1ndar<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Per\u00edodo de medici\u00f3n<\/td>\n<td width=\"391\">De 30 minutos a 24 horas, con capacidad de ampliaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Desviaci\u00f3n cero<\/td>\n<td width=\"391\">\u00b1 8% F. S<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Desviaci\u00f3n del rango<\/td>\n<td width=\"391\">\u00b1 8% F. S<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Repetibilidad<\/td>\n<td width=\"391\">\u22648%<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Precisi\u00f3n<\/td>\n<td width=\"391\">\u00b1 10%<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">MBTF<\/td>\n<td width=\"391\">&gt; 720 horas<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Datos almacenados<\/td>\n<td width=\"391\">Cinco a\u00f1os de almacenamiento de datos<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Interfaz de comunicaci\u00f3n<\/td>\n<td width=\"391\">4-20 mA, RS-232, RS-485, contacto seco<\/td>\n<\/tr>\n<tr>\n<td width=\"146\">Dimensi\u00f3n del contorno<\/td>\n<td width=\"391\">505 \u00d7 395 \u00d7 671 (mm)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"_Toc66953356\"><\/a><strong>Principio y Aplicaci\u00f3n del Analizador de Cadmio Total<\/strong><\/h3>\n<p>La contaminaci\u00f3n del cadmio en el agua proviene principalmente de la escorrent\u00eda superficial y de aguas residuales industriales. Aunque el cadmio es un metal con baja toxicidad, sus compuestos son altamente t\u00f3xicos. Normalmente, el envenenamiento de cadmio en el cuerpo humano es causado principalmente por la ingesti\u00f3n de agua contaminada por cadmio, alimentos y aire a trav\u00e9s del tracto digestivo y el tracto respiratorio. En el cuerpo humano se acumula principalmente en el h\u00edgado, el ri\u00f1\u00f3n y el hueso, causando lesiones de \u00f3rganos y afectan las actividades normales de las personas.<\/p>\n<p>Principio: en la soluci\u00f3n de amortiguaci\u00f3n, a\u00f1adir agente de enmascaramiento para enmascarar la interferencia de otros iones, iones de cadmio y reactivos de cadmio para producir un complejo naranja estable, la absorci\u00f3n compleja es proporcional al contenido de cadmio en la muestra de agua, el contenido de cadmio en agua se calcul\u00f3 midiendo la absorci\u00f3n del complejo.<\/p>\n<p>Es adecuado para el an\u00e1lisis en analizadores de laboratorio o en procesos de producci\u00f3n industrial, as\u00ed como para el an\u00e1lisis de aguas residuales, aguas residuales dom\u00e9sticas urbanas, r\u00edos, lagos, mares y otras aguas superficiales.<\/p>","protected":false},"excerpt":{"rendered":"<p>Online Total Cadmium Analyzer KTG600 es un equipo de monitoreo de calidad del agua. Que se utiliza para monitorear el contenido total de Cadmio en agua.<\/p>","protected":false},"featured_media":1252,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"","youtube_video":"","youtube_video_2":"","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"","product_3d_model":"","document":19046,"file_name_1":"","3d_document":0,"file_name_2":"","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":0,"case1_title":"","case1_link":"","case2_image":0,"case2_title":"","case2_link":"","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[31],"product_tag":[41,34],"class_list":["post-1251","product","type-product","status-publish","has-post-thumbnail","product_cat-toxic-component-analyzer","product_tag-online-total-cadmium-analyzer","product_tag-water-quality-analyzer","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product\/1251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/comments?post=1251"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product\/1251\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media\/1252"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media?parent=1251"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_brand?post=1251"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_cat?post=1251"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_tag?post=1251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}