{"id":22806,"date":"2026-01-20T06:15:09","date_gmt":"2026-01-20T06:15:09","guid":{"rendered":"https:\/\/www.kcsensor.com\/?post_type=product&#038;p=22806"},"modified":"2026-04-02T01:32:28","modified_gmt":"2026-04-02T01:32:28","slug":"kws-650c-online-dissolved-oxygen-sensor","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/es\/product\/kws-650c-online-dissolved-oxygen-sensor\/","title":{"rendered":"Sensor de ox\u00edgeno disuelto en l\u00ednea KWS-650C"},"content":{"rendered":"<h3><strong>Introducci\u00f3n<\/strong><\/h3>\n<p>El sensor de ox\u00edgeno disuelto por fluorescencia en l\u00ednea integrado KWS-650C est\u00e1 dise\u00f1ado bas\u00e1ndose en el principio f\u00edsico de la extinci\u00f3n de la fluorescencia excitada por sustancias espec\u00edficas. Cuando la luz de excitaci\u00f3n incide sobre la sustancia fluorescente situada en la superficie del cabezal de membrana fluorescente, esta se excita y emite fluorescencia. El tiempo de extinci\u00f3n de la fluorescencia se ve afectado por la concentraci\u00f3n de mol\u00e9culas de ox\u00edgeno en la superficie del cabezal de membrana fluorescente. La concentraci\u00f3n de mol\u00e9culas de ox\u00edgeno se puede calcular detectando la diferencia de fase entre la fluorescencia y la luz de excitaci\u00f3n y compar\u00e1ndola con la curva de calibraci\u00f3n interna; el valor final se muestra tras la compensaci\u00f3n de temperatura y salinidad.<\/p>\n<p><img data-dominant-color=\"eeeff0\" data-has-transparency=\"false\" style=\"--dominant-color: #eeeff0;\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-22809 not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-Schematic-diagram.webp\" alt=\"Diagrama esquem\u00e1tico del sensor de ox\u00edgeno disuelto en l\u00ednea KWS-650C\" width=\"501\" height=\"296\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-Schematic-diagram.webp 501w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-Schematic-diagram-300x177.webp 300w\" sizes=\"(max-width: 501px) 100vw, 501px\" \/><\/p>\n<h3><strong>Caracter\u00edstica \u00a0\u00a0<\/strong><\/h3>\n<ul>\n<li>No se necesita ning\u00fan electrolito y no se polarizar\u00e1.<\/li>\n<li>No consume ox\u00edgeno, no se ve afectado por el caudal.<\/li>\n<li>Sensor de temperatura integrado, compensaci\u00f3n autom\u00e1tica de temperatura.<\/li>\n<li>Compensaci\u00f3n de salinidad integrada, configuraci\u00f3n flexible de los par\u00e1metros.<\/li>\n<li>Libre de interferencias causadas por sustancias qu\u00edmicas como los sulfuros.<\/li>\n<li>Peque\u00f1a desviaci\u00f3n, reacci\u00f3n r\u00e1pida, medici\u00f3n m\u00e1s precisa.<\/li>\n<li>Ciclo de vida \u00fatil prolongado, menor costo de uso.<\/li>\n<li>Simple sustituci\u00f3n de la tapa del fluorescente.<\/li>\n<li>Interfaz R-485, protocolo Modbus\/RTU.<\/li>\n<li>Bajo consumo de energ\u00eda, resistente a las interferencias.<\/li>\n<\/ul>\n<h3><strong>Dimensi\u00f3n<\/strong><\/h3>\n<p><img data-dominant-color=\"f8f8f8\" data-has-transparency=\"false\" style=\"--dominant-color: #f8f8f8;\" decoding=\"async\" class=\"alignnone size-full wp-image-22808 not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-dimension.webp\" alt=\"Dimensiones del sensor de ox\u00edgeno disuelto en l\u00ednea KWS-650C\" width=\"772\" height=\"233\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-dimension.webp 772w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-dimension-300x91.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-dimension-768x232.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-Online-Dissolved-Oxygen-Sensor-dimension-600x181.webp 600w\" sizes=\"(max-width: 772px) 100vw, 772px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>El sensor integrado de ox\u00edgeno disuelto por fluorescencia en l\u00ednea KWS-650C se ha dise\u00f1ado bas\u00e1ndose en el principio f\u00edsico de la extinci\u00f3n de la fluorescencia excitada por sustancias espec\u00edficas.<\/p>","protected":false},"featured_media":22810,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"[table id=99 \/]","youtube_video":"","youtube_video_2":"https:\/\/youtu.be\/xwBm4ulwMF4","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"KWS-650C Dissolved Oxygen Sensor Tutorial | Introduction + Wiring + Read Data","product_3d_model":"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2026\/01\/KWS-650C-V1.glb","document":24157,"file_name_1":"KWS-650C-Online-Dissolved-Oxygen-Sensor-Manual v1.0.pdf","3d_document":23154,"file_name_2":"KWS-650C-Online-Dissolved-Oxygen-Sensor 3D File.zip","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":15347,"case1_title":"Wireless Monitoring System for Offshore Cage Aquaculture","case1_link":"https:\/\/www.kcsensor.com\/wireless-monitoring-system-for-offshore-cage-aquaculture\/","case2_image":23882,"case2_title":"Shrimp Farming Water Monitoring","case2_link":"https:\/\/www.kcsensor.com\/do-sensor-shrimp-farming-water-monitoring\/","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[130,131,235],"product_tag":[458],"class_list":["post-22806","product","type-product","status-publish","has-post-thumbnail","product_cat-dissolved-oxygen-sensor","product_cat-do-sensor","product_cat-water-quality-sensor","product_tag-kws-650c-online-dissolved-oxygen-sensor","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product\/22806","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/comments?post=22806"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product\/22806\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media\/22810"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/media?parent=22806"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_brand?post=22806"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_cat?post=22806"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/es\/wp-json\/wp\/v2\/product_tag?post=22806"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}