{"id":19804,"date":"2025-07-01T03:19:11","date_gmt":"2025-07-01T03:19:11","guid":{"rendered":"https:\/\/www.kcsensor.com\/?p=19804"},"modified":"2025-10-16T01:54:52","modified_gmt":"2025-10-16T01:54:52","slug":"ultrasonic-level-meter-universal-power-adaptation-test-and-grounding-solutions","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/ms\/ultrasonic-level-meter-universal-power-adaptation-test-and-grounding-solutions\/","title":{"rendered":"Pengukur Paras Ultrasonik, Penyesuaian Kuasa Universal, Ujian dan Penyelesaian Penyetelan Tanah"},"content":{"rendered":"<h4 class=\"wp-block-heading\"><strong>1. Latar Belakang Masalah: Anomali yang Disebabkan oleh Bekalan Kuasa Sejagat<\/strong><\/h4>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\">Semasa menggunakan meter paras ultrasonik siri KUS dengan bekalan kuasa sejagat 220V ke 24V\/12V, pelanggan menghadapi dua isu utama:<\/p>\n\n\n\n<ol class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-2\">\n<li>Kegagalan komunikasi bersiri (penghentian komunikasi RS485);<\/li>\n\n\n\n<li>Penyimpangan pengukuran (jarak sebenar 3m menunjukkan fluktuasi sekitar 1m).<br>Modul kuasa yang diuji:<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-3\">\n<li>Modul 220V AC ke 24V DC<\/li>\n\n\n\n<li>Modul 220V AC ke 12V DC<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"6f665b\" data-has-transparency=\"true\" style=\"--dominant-color: #6f665b;\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"734\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90-1024x734.webp\" alt=\"\" class=\"wp-image-20110 has-transparency\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90-1024x734.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90-300x215.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90-768x551.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90-600x430.webp 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/\u63a5\u7535\u6e90.webp 1153w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2. Rekod Ujian Modul Kuasa DC 12V<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Jadual 1: Langkah-langkah Ujian Modul Kuasa 12V dan Keputusan<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-black-color has-text-color has-link-color\"><thead><tr><th>Langkah Ujian<\/th><th>Butiran Operasi<\/th><th>Keputusan Ujian<\/th><\/tr><\/thead><tbody><tr><td>1. Pengukuran Ripple<\/td><td>Probe osiloskop yang disambungkan ke V+ dan V-, penghubung AC, had jalur lebar 20MHz<\/td><td>Gelombang ripple: 20~30mV gelombang segitiga, menolak ripple sebagai punca ralat pengukuran<\/td><\/tr><tr><td>2. Ujian tidak berpijak<\/td><td>Modul kuasa tidak disalurkan ke bumi, sensor mengukur jarak sebenar 3m<\/td><td>Pengukuran berfluktuasi sekitar 1m, pelarasan ambang tidak sah; normal selepas beralih ke bekalan kuasa bangku.<\/td><\/tr><tr><td>3. Ujian Berasaskan Bumi<\/td><td>Modul kuasa disalurkan ke bumi, kabel sensor dijauhkan daripada wayar 220V.<\/td><td>Pengukuran tepat (3m); ralat muncul semula apabila kabel berhampiran wayar 220V.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"556560\" data-has-transparency=\"true\" style=\"--dominant-color: #556560;\" decoding=\"async\" width=\"895\" height=\"769\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/12V-\u793a\u6ce2\u5668\u663e\u793a.webp\" alt=\"\" class=\"wp-image-20108 has-transparency\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/12V-\u793a\u6ce2\u5668\u663e\u793a.webp 895w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/12V-\u793a\u6ce2\u5668\u663e\u793a-300x258.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/12V-\u793a\u6ce2\u5668\u663e\u793a-768x660.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/12V-\u793a\u6ce2\u5668\u663e\u793a-600x516.webp 600w\" sizes=\"(max-width: 895px) 100vw, 895px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>3. Ujian Modul Kuasa DC 24V dan Analisis Kegagalan Komunikasi<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Jadual 2: Ujian Modul Kuasa 24V berbanding Isu Komunikasi<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-black-color has-text-color has-link-color\"><thead><tr><th>Senario Ujian<\/th><th>Status Grounding<\/th><th>Prestasi Komunikasi RS485<\/th><th>Keputusan Pengukuran<\/th><th>Ciri-ciri Gelombang Gangguan<\/th><\/tr><\/thead><tbody><tr><td>Ujian Standard<\/td><td>Tidak berbumi<\/td><td>Kegagalan komunikasi yang kerap, sambungan kadang-kadang<\/td><td>Ukuran tidak normal, pelarasan ambang tidak sah<\/td><td>Gangguan puncak-ke-puncak 13V, 50Hz (pengkopling bekalan utama)<\/td><\/tr><tr><td>Ujian yang dioptimumkan<\/td><td>Grounded + GND disambungkan ke V-<\/td><td>Komunikasi yang stabil, tiada gangguan<\/td><td>Pengukuran tepat yang sepadan dengan jarak sebenar<\/td><td>Tiada gangguan yang jelas (Rajah 3)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Punca utama kegagalan komunikasi<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-4\">\n<li>Arus terapung V+ dan V- menghasilkan perbezaan potensi antara isyarat RS485 dan bumi, menyebabkan gangguan.<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-5\">Penyelesaian: Hubungkan GND secara singkat ke V- untuk menghapuskan perbezaan potensi (Rajah 4).<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>4. Empat Titik Kunci untuk Penyesuaian Kuasa Universal (Ringkasan)<\/strong><\/h4>\n\n\n\n<ol class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-6\">\n<li><strong>Keutamaan Grounding<\/strong>Modul kuasa mesti dibumikan dengan baik untuk menyelaraskan V- dengan potensi bumi;<\/li>\n\n\n\n<li><strong>Isyarat Tanah Tinggi<\/strong>: Sambungkan GND ke V- untuk menyelesaikan perbezaan potensi RS485;<\/li>\n\n\n\n<li><strong>Pengasingan kabel<\/strong>: Pastikan jarak \u226530cm antara kabel sensor dan wayar 220V;<\/li>\n\n\n\n<li><strong>Amaran Keselamatan<\/strong>Larangkan kabel sensor daripada bersentuhan dengan voltan tinggi 220V untuk mengelakkan kejutan elektrik.<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>5. Perbandingan Bentuk Gelombang dan Penindasan Gangguan<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>(1)V+ ke bumi gangguan (tidak dibumikan)<\/strong>: 42.8V puncak-puncak, gangguan arus utama 50Hz ;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"7a7f7c\" data-has-transparency=\"true\" style=\"--dominant-color: #7a7f7c;\" decoding=\"async\" width=\"1024\" height=\"655\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3-1024x655.webp\" alt=\"\" class=\"wp-image-20109 has-transparency\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3-1024x655.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3-300x192.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3-768x491.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3-600x384.webp 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/07\/24V-\u793a\u6ce2\u5668\u663e\u793a3.webp 1151w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>(2) isyarat RS485 (dibumikan)<\/strong>Gangguan dihapuskan, kestabilan komunikasi 100%. .<\/p>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-7\"><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>1. Problem Background: Anomalies Caused by Universal Power Supplies During the use of KUS series ultrasonic level meters with 220V to 24V\/12V universal power supplies, customers encountered two key issues: 2. 12V DC Power Module Test Record Table 1: 12V Power Module Test Steps and Results Test Step Operation Details Test Results 1. Ripple Measurement [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[114],"tags":[],"class_list":["post-19804","post","type-post","status-publish","format-standard","hentry","category-ultrasonic-sensor"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/posts\/19804","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/comments?post=19804"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/posts\/19804\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/media?parent=19804"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/categories?post=19804"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/ms\/wp-json\/wp\/v2\/tags?post=19804"}],"curies":[{"name":"Perancis","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}