{"id":19735,"date":"2025-06-16T06:31:24","date_gmt":"2025-06-16T06:31:24","guid":{"rendered":"https:\/\/www.kcsensor.com\/?post_type=product&#038;p=19735"},"modified":"2026-02-09T07:31:37","modified_gmt":"2026-02-09T07:31:37","slug":"tdlas200a-laser-methane-sensor-pump","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/nl\/product\/tdlas200a-laser-methane-sensor-pump\/","title":{"rendered":"TDLAS200A Lasermethaansensor-pomp"},"content":{"rendered":"<h3><strong>1. Inleiding<\/strong><strong>\u00a0<\/strong><\/h3>\n<p>De TDLAS200A-lasergastelemetriemodule is vervaardigd op basis van laserabsorptiespectroscopietechnologie. Het apparaat zendt een laserstraal met een specifieke golflengte uit om te detecteren of er een doelgas aanwezig is in het optische pad van de laser, waardoor de concentratie van het doelgas wordt bepaald.<\/p>\n<h3><strong>2. Kenmerken<\/strong><\/h3>\n<ul>\n<li>Zeer hoge gevoeligheid, reageert uitsluitend op het doelgas<\/li>\n<li>Ingebouwde referentiecel, kan automatisch worden gekalibreerd<\/li>\n<li>Eenvoudig te integreren; de digitale interface geeft de status en concentratie direct weer<\/li>\n<\/ul>\n<h3><strong>3. Meetprincipe<\/strong><\/h3>\n<p>\u201cMethaanmoleculen absorberen licht met een bepaalde golflengte\u201d \u2013 Moleculair absorptiespectrum<\/p>\n<p>\u201cDe hoeveelheid licht die door een transparant medium (een methaangaswolk) wordt geabsorbeerd, is evenredig met de dikte en de concentratie van de gaswolk\u201d \u2013 de wet van Beer-Lambert<\/p>\n<p>Volgens de bovengenoemde natuurkundige principes kan een lichtstraal met een specifieke golflengte worden gebruikt om door de lekkende methaanmass te dringen. Aan de hand van de mate waarin de lichtstraal wordt verzwakt, kan de methaanconcentratie in de gasmassa worden gemeten, en het systeem reageert uitsluitend op methaan (unieke selectiviteit).<\/p>\n<p>Door gebruik te maken van een detectiecel met meerdere reflecties en de laser herhaaldelijk door het te meten gas te laten gaan, kan de detectiegevoeligheid worden vergroot.<\/p>\n<p><img data-dominant-color=\"dfe0e3\" data-has-transparency=\"false\" style=\"--dominant-color: #dfe0e3;\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19715 not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor.webp\" alt=\"Laser-methaansensor\" width=\"597\" height=\"273\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor.webp 597w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor-300x137.webp 300w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><\/p>\n<h3><strong>4. Afmetingen<\/strong><\/h3>\n<p><img data-dominant-color=\"f9f9fa\" data-has-transparency=\"false\" style=\"--dominant-color: #f9f9fa;\" decoding=\"async\" class=\"alignnone size-full wp-image-19714 not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor-Dimension.webp\" alt=\"Afmetingen van de lasermethaansensor\" width=\"722\" height=\"442\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor-Dimension.webp 722w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor-Dimension-300x184.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/06\/Laser-Methane-Sensor-Dimension-600x367.webp 600w\" sizes=\"(max-width: 722px) 100vw, 722px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>De TDLAS200A Laser Methaan Sensor telemetrie module wordt vervaardigd op basis van laserabsorptie spectroscopie technologie. Het zendt een laserstraal van een specifieke golflengte uit om te detecteren of er een doelgas is in het optische padbereik van de laser, waardoor de concentratie van het doelgas wordt verkregen.<\/p>\n<p><a href=\"\/wp-content\/uploads\/2025\/06\/TDLAS200-Series-Module-Disassembly-and-Maintenance.pdf\">TDLAS200 Series Module demontage en onderhoud.pdf<\/a><\/p>","protected":false},"featured_media":19896,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"[table id=131 \/]","youtube_video":"","youtube_video_2":"https:\/\/www.youtube.com\/watch?v=S9g4VGFeXCU","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"TDLAS200 Series Laser Methane Gas Sensor Wiring Guide Video","product_3d_model":"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/12\/TDLAS200A.glb","document":20319,"file_name_1":"TDLAS200 Series Laser Methane Sensor_V1.4.pdf","3d_document":22034,"file_name_2":"TDLAS200A Laser Methane Sensor 3D file.zip","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":23858,"case1_title":"Agricultural Chamber Gas Monitoring","case1_link":"https:\/\/www.kcsensor.com\/laser-methane-sensor-agricultural-gas-monitoring\/","case2_image":0,"case2_title":"","case2_link":"","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[385,386],"product_tag":[403],"class_list":["post-19735","product","type-product","status-publish","has-post-thumbnail","product_cat-gas-sensor","product_cat-td-las","product_tag-tdlas200a-laser-methane-sensor-pump","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product\/19735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/comments?post=19735"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product\/19735\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/media\/19896"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/media?parent=19735"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product_brand?post=19735"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product_cat?post=19735"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/nl\/wp-json\/wp\/v2\/product_tag?post=19735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}