{"id":1316,"date":"2021-03-23T16:39:38","date_gmt":"2021-03-23T16:39:38","guid":{"rendered":"https:\/\/kcsensor.com\/?post_type=product&#038;p=1316"},"modified":"2025-04-09T07:57:32","modified_gmt":"2025-04-09T07:57:32","slug":"online-permanganate-analyzer-kpe600","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/pl\/product\/online-permanganate-analyzer-kpe600\/","title":{"rendered":"Analizator nadmanganianu online KPE600"},"content":{"rendered":"<h3><strong>Dane techniczne<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"152\">Model<\/td>\n<td width=\"391\">KPE600<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Parametr monitorowania<\/td>\n<td width=\"391\">Tlenganian<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Metoda<\/td>\n<td width=\"391\">utlenianie nadmanganianu potasu, spektrofotometr<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Zakres<\/td>\n<td width=\"391\">0\u201320 mg\/l<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Granica wykrywalno\u015bci<\/td>\n<td width=\"391\">\u2264 0, 05 mg \/ L<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Jednostka wy\u015bwietlaj\u0105ca<\/td>\n<td width=\"391\">Wy\u015bwietlacz matrycowy 12232, podw\u00f3jny wy\u015bwietlacz z 7-calowym ekranem dotykowym LCD<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Tryb pomiaru<\/td>\n<td width=\"391\">Pomiar r\u0119czny, pomiar ci\u0105g\u0142y, okresowy<\/p>\n<p>pomiar, pomiar punktowy, automatyczny pomiar kalibracji, standardowa weryfikacja roztworu<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Okres pomiarowy<\/td>\n<td width=\"391\">30 minut do 24 godzin, z regulowan\u0105 ekspansj\u0105<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Zero dryfu<\/td>\n<td width=\"391\">\u2264 \u00b1 0,2%<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Odchylenie zakresu<\/td>\n<td width=\"391\">\u2264 \u00b1 1,51 TP3T<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Powtarzalno\u015b\u0107<\/td>\n<td width=\"391\">\u2264 \u00b1 0, 8%<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Badanie glukozy<\/td>\n<td width=\"391\">\u2264 \u00b1 2,2%<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">MBTF<\/td>\n<td width=\"391\">14 400 godzin<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Przechowywane dane<\/td>\n<td width=\"391\">Pi\u0119\u0107 lat przechowywania danych<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Interfejs komunikacyjny<\/td>\n<td width=\"391\">4- 20mA, RS232, RS485, kontakt suchy<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">Wymiar konturowy<\/td>\n<td width=\"391\">505 * 395 * 671 (mm)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a name=\"_Toc66953327\"><\/a>Zasady i zastosowanie sta\u0142e<\/h2>\n<p>Wska\u017anik nadmanganianu odnosi si\u0119 do utleniania niekt\u00f3rych organicznych i nieorganicznych substancji redukuj\u0105cych w pr\u00f3bkach wody przez nadmanganian potasu w okre\u015blonych warunkach oraz do obliczania r\u00f3wnowa\u017cnej masy tlenu przez zu\u017cyty nadmanganian potasu. Jest to kompleksowy wska\u017anik oceny jako\u015bci wody, kt\u00f3ry odzwierciedla stopie\u0144 zanieczyszczenia tlenk\u00f3w organicznych i nieorganicznych w wodzie.<\/p>\n<p>Jak to dzia\u0142a: pr\u00f3bka wody jest mieszana z nadmiarem kwasu nadmanganianu, zakwaszony st\u0119\u017conym kwasem siarkowym, i zredukowany do nadmanganianu w wysokiej temperaturze i ci\u015bnieniu, zmieniaj\u0105c w ten spos\u00f3b kolor mieszanego roztworu, stopie\u0144 zmiany koloru roztworu odpowiada wska\u017anikowi nadmanganianu w pr\u00f3bce wody. Wska\u017anik stacjonarny w pr\u00f3bce wody oblicza si\u0119 poprzez pomiar roztworu mieszanego.<\/p>\n<p>G\u0142\u00f3wnymi scenariuszami zastosowania s\u0105 wody podziemne, woda rzeczna, jako\u015b\u0107 wody w jeziorze, lepsze monitorowanie jako\u015bci wody w indeksie stacjonarnym.<\/p>","protected":false},"excerpt":{"rendered":"<p>Wska\u017anik nadmanganianu odnosi si\u0119 do utleniania niekt\u00f3rych organicznych i nieorganicznych substancji redukuj\u0105cych w pr\u00f3bkach wody przez nadmanganian potasu w okre\u015blonych warunkach oraz do obliczania r\u00f3wnowa\u017cnej masy tlenu przez zu\u017cyty nadmanganian potasu. Jest to kompleksowy wska\u017anik oceny jako\u015bci wody, kt\u00f3ry odzwierciedla stopie\u0144 zanieczyszczenia tlenk\u00f3w organicznych i nieorganicznych w wodzie.<\/p>","protected":false},"featured_media":1317,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"","youtube_video":"","youtube_video_2":"","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"","product_3d_model":"","document":19046,"file_name_1":"","3d_document":0,"file_name_2":"","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":0,"case1_title":"","case1_link":"","case2_image":0,"case2_title":"","case2_link":"","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[31],"product_tag":[52,34],"class_list":["post-1316","product","type-product","status-publish","has-post-thumbnail","product_cat-toxic-component-analyzer","product_tag-online-permanganate-analyzer","product_tag-water-quality-analyzer","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product\/1316","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/comments?post=1316"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product\/1316\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/media\/1317"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/media?parent=1316"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_brand?post=1316"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_cat?post=1316"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_tag?post=1316"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}