{"id":18591,"date":"2025-03-13T02:35:05","date_gmt":"2025-03-13T02:35:05","guid":{"rendered":"https:\/\/www.kcsensor.com\/?post_type=product&#038;p=18591"},"modified":"2026-01-23T07:47:00","modified_gmt":"2026-01-23T07:47:00","slug":"kgf125-gear-flow-meter","status":"publish","type":"product","link":"https:\/\/www.kcsensor.com\/pl\/product\/kgf125-gear-flow-meter\/","title":{"rendered":"Przep\u0142ywomierz z\u0119baty KGF125"},"content":{"rendered":"<h3><strong><b>Wprowadzenie<\/b><\/strong><\/h3>\n<p>Przep\u0142ywomierz z\u0119baty nale\u017cy do grupy przetwornik\u00f3w przep\u0142ywu obj\u0119to\u015bciowego i mo\u017ce s\u0142u\u017cy\u0107 do precyzyjnego pomiaru obj\u0119to\u015bci oraz nat\u0119\u017cenia przep\u0142ywu. Przep\u0142ywaj\u0105ce medium powoduje zaz\u0119bienie i obr\u00f3t k\u00f3\u0142 z\u0119batych. Pod wp\u0142ywem przep\u0142ywu p\u0142ynu powstaje r\u00f3\u017cnica ci\u015bnie\u0144 mi\u0119dzy wlotem a wylotem przyrz\u0105du. Jedna para k\u00f3\u0142 z\u0119batych mo\u017ce obraca\u0107 si\u0119 swobodnie bez konieczno\u015bci zasilania. Pusta przestrze\u0144 mi\u0119dzy ko\u0142ami z\u0119batymi jest wype\u0142niona ciecz\u0105, kt\u00f3ra jest wypychana na zewn\u0105trz w wyniku obrotu. Ciecz przep\u0142ywaj\u0105ca przez przyrz\u0105d oraz jej nat\u0119\u017cenie przep\u0142ywu mo\u017cna okre\u015bli\u0107 poprzez pomiar liczby obrot\u00f3w k\u00f3\u0142 z\u0119batych.<\/p>\n<h3><strong>zasada<\/strong><\/h3>\n<p>Pr\u0119dko\u015b\u0107 obrotowa nadajnika jest wykrywana przez cewk\u0119 czujnikow\u0105 umieszczon\u0105 wewn\u0105trz wzmacniacza sygna\u0142u w obudowie. Wzmacniacz sygna\u0142u nie mo\u017ce mie\u0107 kontaktu z mierzonym medium. Linia si\u0142y magnetycznej generowana wewn\u0105trz magnesu sta\u0142ego w obudowie w wyniku obracania si\u0119 przek\u0142adni nadajnika powoduje zmian\u0119 strumienia magnetycznego w cewce czujnikowej. Cewka czujnikowa wysy\u0142a sygna\u0142 wykrytego cyklu zmiany strumienia do przedwzmacniacza w celu wzmocnienia i ukszta\u0142towania sygna\u0142u. Sygna\u0142 impulsowy, kt\u00f3ry jest w bezpo\u015bredniej zale\u017cno\u015bci od pr\u0119dko\u015bci przep\u0142ywu, zostanie przes\u0142any do obwodu konwersji jednostkowej i integracji przep\u0142ywu w celu uzyskania i wy\u015bwietlenia skumulowanego przep\u0142ywu. Jednocze\u015bnie sygna\u0142 impulsowy zostanie r\u00f3wnie\u017c przes\u0142any do obwodu konwersji cz\u0119stotliwo\u015bci na pr\u0105d w celu przekszta\u0142cenia sygna\u0142u impulsowego na symulowan\u0105 warto\u015b\u0107 nat\u0119\u017cenia pr\u0105du, co pozwoli na wy\u015bwietlenie chwilowej warto\u015bci przep\u0142ywu.<\/p>\n<p>Przep\u0142ywomierz z\u0119baty charakteryzuje si\u0119 wysok\u0105 precyzj\u0105 pomiaru i umo\u017cliwia precyzyjny monta\u017c. Obr\u00f3t k\u00f3\u0142 z\u0119batych jest skanowany bezkontaktowo. Ka\u017cde ko\u0142o z\u0119bate generuje jeden impuls o bardzo wysokiej rozdzielczo\u015bci. Przek\u0142adnia kolumnowa pozwala na pomiar cieczy o bardzo ma\u0142ym nat\u0119\u017ceniu przep\u0142ywu i niewielkiej obj\u0119to\u015bci.<\/p>\n<p><img data-dominant-color=\"e9e9e8\" data-has-transparency=\"false\" style=\"--dominant-color: #e9e9e8;\" fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-18593 size-full aligncenter not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-\u539f\u7406\u56fe-png.webp\" alt=\"Schemat przep\u0142ywomierza z\u0119batego KGF125\" width=\"382\" height=\"314\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-\u539f\u7406\u56fe-png.webp 382w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-\u539f\u7406\u56fe-300x247.webp 300w\" sizes=\"(max-width: 382px) 100vw, 382px\" \/><\/p>\n<h3><strong><b>Zastosowanie<\/b><\/strong><\/h3>\n<ul>\n<li>Odmierzanie \u017cywicy i kleju<\/li>\n<li>Pomiar oleju hydraulicznego, oleju smarowego i smaru<\/li>\n<li>Pomiar oleju opa\u0142owego<\/li>\n<li>Pomiar farby drukarskiej i asfaltu<\/li>\n<li>Pomiar azotu ciek\u0142ego, czynnika ch\u0142odniczego i rozpuszczalnika<\/li>\n<li>Pomiar oleju spo\u017cywczego, oleju rybnego i konserw spo\u017cywczych<\/li>\n<li>System ilo\u015bciowej regulacji przep\u0142ywu p\u0142yn\u00f3w<\/li>\n<\/ul>\n<h3><strong><b>Funkcje \u00a0\u00a0<\/b><\/strong><\/h3>\n<ul>\n<li>Sygna\u0142 steruj\u0105cy, wyj\u015bcie 4\u201320 mA oraz RS-485<\/li>\n<li>Odporno\u015b\u0107 na wysokie ci\u015bnienie (1,0\u201345 MPa)<\/li>\n<li>Odporno\u015b\u0107 na wysokie i niskie temperatury (-196 \u2103\u2013170 \u2103)<\/li>\n<li>Umo\u017cliwia pomiar r\u00f3\u017cnych rodzaj\u00f3w medi\u00f3w lepkich.<\/li>\n<li>Wysoka precyzja i powtarzalno\u015b\u0107<\/li>\n<li>Zakres powi\u0119kszenia (1:100)<\/li>\n<li>Szeroki zakres pomiarowy<\/li>\n<li>Wysoka odporno\u015b\u0107 na korozj\u0119 i czynniki zanieczyszczaj\u0105ce (kwasy i zasady)<\/li>\n<\/ul>\n<h3><strong><b>Wymiar<\/b><\/strong><\/h3>\n<p><img data-dominant-color=\"f8f8f8\" data-has-transparency=\"false\" style=\"--dominant-color: #f8f8f8;\" decoding=\"async\" class=\"alignnone wp-image-18592 size-full not-transparent\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-png.webp\" alt=\"Wymiary przep\u0142ywomierza z\u0119batego KGF125\" width=\"1056\" height=\"321\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-png.webp 1056w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-300x91.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-1024x311.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-768x233.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/03\/KGF125-Dimension-600x182.webp 600w\" sizes=\"(max-width: 1056px) 100vw, 1056px\" \/><\/p>\n<p>Jednostka: mm<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"120\">Model<\/td>\n<td width=\"75\">A<\/td>\n<td width=\"72\">B<\/td>\n<td width=\"79\">C<\/td>\n<td width=\"78\">D<\/td>\n<td width=\"83\">E<\/td>\n<td width=\"79\">F<\/td>\n<td width=\"79\">G<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF102<\/td>\n<td width=\"75\">\u03a683<\/td>\n<td width=\"72\">80<\/td>\n<td width=\"79\">50<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G1\/4<\/td>\n<td width=\"79\">40<\/td>\n<td width=\"79\">M6<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF104<\/td>\n<td width=\"75\">\u03a683<\/td>\n<td width=\"72\">80<\/td>\n<td width=\"79\">50<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G1\/4<\/td>\n<td width=\"79\">55<\/td>\n<td width=\"79\">M6<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF106<\/td>\n<td width=\"75\">\u03a683<\/td>\n<td width=\"72\">80<\/td>\n<td width=\"79\">62<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G1\/2<\/td>\n<td width=\"79\">55<\/td>\n<td width=\"79\">M6<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF110<\/td>\n<td width=\"75\">\u03a683<\/td>\n<td width=\"72\">80<\/td>\n<td width=\"79\">62<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G1\/2<\/td>\n<td width=\"79\">55<\/td>\n<td width=\"79\">M6<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF115<\/td>\n<td width=\"75\">\u03a6113<\/td>\n<td width=\"72\">110<\/td>\n<td width=\"79\">62<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G3\/4<\/td>\n<td width=\"79\">90<\/td>\n<td width=\"79\">,M6<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF125<\/td>\n<td width=\"75\">\u03a6158<\/td>\n<td width=\"72\">140<\/td>\n<td width=\"79\">85<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">G1<\/td>\n<td width=\"79\">110<\/td>\n<td width=\"79\">M8<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">KGF132<\/td>\n<td width=\"75\">\u03a6218<\/td>\n<td width=\"72\">160<\/td>\n<td width=\"79\">100<\/td>\n<td width=\"78\">70<\/td>\n<td width=\"83\">M35*1,5<\/td>\n<td width=\"79\">180<\/td>\n<td width=\"79\">M8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Podane powy\u017cej rozmiary dotycz\u0105 produkt\u00f3w standardowych. Mo\u017cliwe jest dostosowanie do indywidualnych potrzeb.<\/p>","protected":false},"excerpt":{"rendered":"<p>Przep\u0142ywomierz z\u0119baty charakteryzuje si\u0119 wysok\u0105 dok\u0142adno\u015bci\u0105 pomiaru i precyzyjnym monta\u017cem. Obr\u00f3t k\u00f3\u0142 z\u0119batych odbywa si\u0119 w trybie skanowania bezkontaktowego. Ka\u017cde ko\u0142o z\u0119bate generuje jeden impuls o wysokiej rozdzielczo\u015bci. Przek\u0142adnia kolumnowa umo\u017cliwia pomiar cieczy o bardzo ma\u0142ym nat\u0119\u017ceniu przep\u0142ywu i niewielkiej obj\u0119to\u015bci.<\/p>","protected":false},"featured_media":18595,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"parameter_table":"[table id=1 \/]","youtube_video":"","youtube_video_2":"","youtube_video_cover_1":0,"video_description_1":"","video_description_2":"The product demonstration video is under preparation and will be released shortly.","product_3d_model":"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/12\/KGF125.glb","document":18594,"file_name_1":" KGF100 Gear Flow Meter Datasheet_v1.3.pdf","3d_document":21900,"file_name_2":"KGF125 Gear Flow Meter 3D file.zip","file_name_3":"","3d_document_3":0,"file_name_4":"","3d_document_4":0,"file_name_5":"","3d_document_5":0,"file_name_6":"","3d_document_6":0,"file_name_7":"","3d_document_7":0,"case1_image":0,"case1_title":"","case1_link":"","case2_image":0,"case2_title":"","case2_link":"","case3_image":0,"case3_title":"","case3_link":""},"product_brand":[],"product_cat":[342],"product_tag":[343],"class_list":["post-18591","product","type-product","status-publish","has-post-thumbnail","product_cat-gear-flow-meter","product_tag-gear-flow-meter","desktop-align-center","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product\/18591","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/comments?post=18591"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product\/18591\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/media\/18595"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/media?parent=18591"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_brand?post=18591"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_cat?post=18591"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pl\/wp-json\/wp\/v2\/product_tag?post=18591"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}