{"id":14175,"date":"2023-01-31T07:39:46","date_gmt":"2023-01-31T07:39:46","guid":{"rendered":"https:\/\/kcsensor.com\/?p=14175"},"modified":"2026-09-28T09:47:29","modified_gmt":"2026-09-28T09:47:29","slug":"a-guide-to-dissolved-oxygen-measurement","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/pt\/a-guide-to-dissolved-oxygen-measurement\/","title":{"rendered":"Um guia para a medi\u00e7\u00e3o do oxig\u00eanio dissolvido"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Um guia para a medi\u00e7\u00e3o do oxig\u00eanio dissolvido. \u00c9 f\u00e1cil pensarmos no oxig\u00eanio do ar que respiramos; no entanto, os l\u00edquidos ao nosso redor tamb\u00e9m cont\u00eam oxig\u00eanio. N\u00e3o \u00e9 como se os seres humanos fossem os \u00fanicos organismos que precisam de oxig\u00eanio para viver. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O uso do oxig\u00eanio \u00e9 de extrema import\u00e2ncia na conserva\u00e7\u00e3o de alimentos, na gest\u00e3o da \u00e1gua e no monitoramento do meio ambiente. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O oxig\u00eanio permanece dissolvido nos l\u00edquidos e \u00e9 por isso que precisamos de um<strong>\u00a0Sensor DO<\/strong>\u00a0para medi-lo, j\u00e1 que se trata de um par\u00e2metro importante em muitos setores.\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Um guia para a medi\u00e7\u00e3o do oxig\u00eanio dissolvido\u00a0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Motivos para realizar testes de oxig\u00eanio dissolvido&nbsp;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O motivo para testar o oxig\u00eanio dissolvido varia de acordo com o setor em que voc\u00ea atua. O motivo pelo qual um en\u00f3logo testa o oxig\u00eanio dissolvido \u00e9 diferente do motivo pelo qual um t\u00e9cnico de laborat\u00f3rio o mede. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A medi\u00e7\u00e3o do OD \u00e9 fundamental no monitoramento ambiental da qualidade da \u00e1gua. Essa medi\u00e7\u00e3o \u00e9 um indicador essencial da sa\u00fade geral do ecossistema. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A prolifera\u00e7\u00e3o bacteriana aumenta \u00e0 medida que os organismos morrem e se decomp\u00f5em. Esse aumento no crescimento bacteriano eleva o consumo de oxig\u00eanio dissolvido (OD), o que resulta em uma redu\u00e7\u00e3o no n\u00edvel de OD. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se houver uma queda no n\u00edvel de oxig\u00eanio dissolvido (OD), surgir\u00e1 uma zona morta, na qual todas as plantas e animais aqu\u00e1ticos morrer\u00e3o. Por esse motivo, a medi\u00e7\u00e3o do OD \u00e9 de vital import\u00e2ncia na aquicultura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A medi\u00e7\u00e3o do OD tamb\u00e9m \u00e9 realizada em laborat\u00f3rios. Existem v\u00e1rias raz\u00f5es cient\u00edficas para essa medi\u00e7\u00e3o. Ela \u00e9 \u00fatil para monitorar a demanda biol\u00f3gica de oxig\u00eanio, a taxa de consumo de oxig\u00eanio e a taxa espec\u00edfica de consumo de oxig\u00eanio.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Os fatores que afetam o n\u00edvel de OD<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">V\u00e1rios fatores afetam o n\u00edvel de oxig\u00eanio dissolvido. Vamos dar uma olhada em alguns deles.&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Temperatura\u00a0<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A temperatura \u00e9 o principal fator que afeta diretamente o n\u00edvel de oxig\u00eanio dissolvido. Com o aumento da temperatura, ocorre um aumento no movimento das part\u00edculas. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Devido a esse aumento, as part\u00edculas de DO podem perder as liga\u00e7\u00f5es que as mant\u00eam unidas dentro do l\u00edquido. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 medida que a temperatura aumenta, ocorre uma queda no n\u00edvel de oxig\u00eanio dissolvido (OD) e, inversamente, quando h\u00e1 uma queda na temperatura, ocorre um aumento na concentra\u00e7\u00e3o de OD.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Press\u00e3o<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A press\u00e3o de que falamos aqui \u00e9 a press\u00e3o atmosf\u00e9rica. Se a press\u00e3o atmosf\u00e9rica diminuir, ocorre uma queda na press\u00e3o parcial do oxig\u00eanio. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Com o aumento da altitude, ocorre uma queda na concentra\u00e7\u00e3o de oxig\u00eanio dissolvido (OD), pois n\u00e3o h\u00e1 press\u00e3o suficiente para manter o oxig\u00eanio dissolvido no l\u00edquido. Da mesma forma, \u00e0 medida que a altitude diminui, o n\u00edvel de OD aumenta.\u00a0<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Salinidade\u00a0<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A salinidade tamb\u00e9m afeta a medi\u00e7\u00e3o do oxig\u00eanio dissolvido (OD) presente em uma solu\u00e7\u00e3o. Isso ocorre porque o oxig\u00eanio exerce menor atra\u00e7\u00e3o pelas mol\u00e9culas de \u00e1gua quando a solu\u00e7\u00e3o cont\u00e9m sal. Portanto, \u00e0 medida que a salinidade diminui, ocorre um aumento no oxig\u00eanio dissolvido.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A Kacise Optronics Co., Ltd. \u00e9 a empresa ideal para se ter um<strong>\u00a0<a href=\"https:\/\/www.kcsensor.com\/pt\/product-category\/do-sensor\/\">Sensor DO<\/a><\/strong>. Temos uma grande variedade desses aparelhos, e voc\u00ea pode escolher o que mais lhe convier.\u00a0<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"Medi\u00e7\u00e3o do oxig\u00eanio dissolvido\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/y7zbmlEaPAs?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Guias relacionados<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.kcsensor.com\/pt\/the-best-way-to-select-the-ideal-dissolved-oxygen-sensor\/\">A melhor maneira de escolher o sensor de oxig\u00eanio dissolvido ideal<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.kcsensor.com\/pt\/what-is-dissolved-oxygen\/\">O que \u00e9 oxig\u00eanio dissolvido<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A guide to dissolved oxygen measurement. We can easily think about the oxygen in the air that we inhale; however, liquids around us also have oxygen. It is not that humans are the only organism that requires oxygen to lead a life. The use of oxygen is of utmost importance in the preservation of food, [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":14441,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[209,113,277],"tags":[],"class_list":["post-14175","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dissolved-oxygen-probe","category-dissolved-oxygen-sensor","category-do-sensor"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts\/14175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/comments?post=14175"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts\/14175\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/media\/14441"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/media?parent=14175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/categories?post=14175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/tags?post=14175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}