{"id":17150,"date":"2024-12-25T02:40:41","date_gmt":"2024-12-25T02:40:41","guid":{"rendered":"https:\/\/kcsensor.com\/?p=17150"},"modified":"2026-09-28T09:32:09","modified_gmt":"2026-09-28T09:32:09","slug":"what-is-a-capacitive-level-sensorpart-3","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/pt\/what-is-a-capacitive-level-sensorpart-3\/","title":{"rendered":"O que \u00e9 um sensor de n\u00edvel capacitivo? Parte 3"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"f9f6f6\" data-has-transparency=\"false\" style=\"--dominant-color: #f9f6f6;\" fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"544\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/12\/part3-png.webp\" alt=\"O que \u00e9 um sensor de n\u00edvel capacitivo? Parte 3\" class=\"wp-image-17151 not-transparent\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/12\/part3-png.webp 1024w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/12\/part3-300x159.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/12\/part3-768x408.webp 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/12\/part3-600x319.webp 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-how-do-you-use-a-capacitive-level-sensor-kslv605\"><strong>Como se utiliza um sensor de n\u00edvel capacitivo? <a href=\"https:\/\/www.kcsensor.com\/pt\/product\/capacitive-level-transmitter\/\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/product\/capacitive-level-transmitter\/\">KSLV605<\/a><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>M\u00e9todo de instala\u00e7\u00e3o<\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>1: Instala\u00e7\u00e3o de fase gasosa e fase l\u00edquida<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"472\" height=\"349\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.1-1.png\" alt=\"Instala\u00e7\u00e3o de fase gasosa e fase l\u00edquida\" class=\"wp-image-13169\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.1-1.png 472w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.1-1-300x222.png 300w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/><figcaption class=\"wp-element-caption\">Figura 3.1<\/figcaption><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Uma vez que os produtos s\u00e3o apenas diferentes em design de apar\u00eancia e material, mas ambos pertencem ao instrumento de medi\u00e7\u00e3o e controle de n\u00edvel de l\u00edquido externo, os m\u00e9todos de instala\u00e7\u00e3o dos dois s\u00e3o basicamente os mesmos, que ser\u00e3o explicados em conjunto aqui. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Em geral, a instala\u00e7\u00e3o \u00e9 extremamente simples e r\u00e1pida, basta conectar a flange de conex\u00e3o de fase g\u00e1s-l\u00edquido na medi\u00e7\u00e3o de n\u00edvel l\u00edquido e instrumento de controle com a flange de fase g\u00e1s-l\u00edquido no equipamento, adicionar uma junta no meio, e corrigi-lo com parafusos. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">(<strong>Observa\u00e7\u00e3o:<\/strong> A flange de liga\u00e7\u00e3o do instrumento de monitoriza\u00e7\u00e3o e controlo do n\u00edvel de l\u00edquido foi soldada de acordo com o tamanho acordado pelas duas partes e n\u00e3o precisa de ser reconfigurada. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">O usu\u00e1rio deve configurar a v\u00e1lvula e pipeline por si mesmo), como mostrado na figura&nbsp;3.1.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Observa\u00e7\u00e3o:<\/strong> Antes da instala\u00e7\u00e3o, certifique-se de limpar o furo interno do tubo de sa\u00edda no equipamento para garantir que o tubo de sa\u00edda do equipamento est\u00e1 desobstru\u00eddo e a superf\u00edcie de veda\u00e7\u00e3o do flange est\u00e1 intacta. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Ao mesmo tempo, uma v\u00e1lvula pode ser adicionada entre a flange do instrumento de medi\u00e7\u00e3o e controle de n\u00edvel l\u00edquido e a flange do equipamento para facilitar a desmontagem e montagem do instrumento durante a manuten\u00e7\u00e3o ou substitui\u00e7\u00e3o.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2: Instala\u00e7\u00e3o do medidor de n\u00edvel de l\u00edquido capacitivo tipo caldeira<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"502\" height=\"452\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.2.png\" alt=\"Instala\u00e7\u00e3o de medidor de n\u00edvel de l\u00edquido capacitivo tipo caldeira\" class=\"wp-image-13170\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.2.png 502w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.2-300x270.png 300w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/><figcaption class=\"wp-element-caption\">Figura 3.2<\/figcaption><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong><a href=\"https:\/\/www.kcsensor.com\/pt\/product\/capacitive-level-transmitter\/\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/product\/capacitive-level-transmitter\/\">Medidor de n\u00edvel de capacidade<\/a><\/strong> \u00e9 um produto especialmente utilizado para sacos de ar de grandes, m\u00e9dias e pequenas caldeiras e outros tipos de medi\u00e7\u00e3o de n\u00edvel de l\u00edquido de alta temperatura.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Adota materiais especiais e tecnologia de frequ\u00eancia de r\u00e1dio, de modo que toda a m\u00e1quina pode funcionar est\u00e1velmente por um longo tempo em um ambiente de alta temperatura. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Por ser especialmente utilizado em ambiente de alta temperatura, a estrutura e o m\u00e9todo de instala\u00e7\u00e3o do instrumento de medi\u00e7\u00e3o e controle de n\u00edvel l\u00edquido s\u00e3o diferentes de outros produtos.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Em primeiro lugar, \u00e9 diferente de outros produtos na medida em que seu transmissor est\u00e1 localizado sob o sensor, h\u00e1 uma se\u00e7\u00e3o selada e dissipadora de calor do cilindro de medi\u00e7\u00e3o para o transmissor, e, em seguida, para baixo \u00e9 um bra\u00e7o curvado de 90 graus para levar o transmissor para o lado do sensor, o que garante que o transmissor est\u00e1 protegido de altas temperaturas perto da porta de g\u00e1s. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Por outro lado, quando o meio de alta temperatura transfere calor para baixo para o transmissor, ele passa pela primeira vez atrav\u00e9s de uma se\u00e7\u00e3o de dissipa\u00e7\u00e3o de calor especial, que ir\u00e1 reduzir muito seu calor. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Levar o transmissor para o lado inferior do sensor \u00e9 principalmente para evitar o vazamento da se\u00e7\u00e3o de veda\u00e7\u00e3o do sensor e impedir que o meio se espalhe para a parte do transmissor ao longo da parede externa do cilindro de medi\u00e7\u00e3o, causando curto-circuito ou corros\u00e3o.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Em suma, a estrutura deste medidor de n\u00edvel tem vantagens \u00f3bvias, raz\u00e3o pela qual ele pode funcionar est\u00e1velmente por um longo tempo em um ambiente de alta temperatura. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Para instala\u00e7\u00e3o, deve-se notar que o transmissor est\u00e1 abaixo, e a dist\u00e2ncia do tubo de esgoto \u00e9 relativamente pr\u00f3xima, de modo que n\u00e3o pode ser instalado ao contr\u00e1rio. A instala\u00e7\u00e3o \u00e9 como mostrado na figura 3.2.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-2-calibration\"><strong>Calibra\u00e7\u00e3o<\/strong><\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Embora o ajuste anal\u00f3gico tenha sido feito antes do produto sair da f\u00e1brica, a fim de permitir ao usu\u00e1rio experimentar mais o desempenho do nosso produto antes do uso, recomenda-se que o usu\u00e1rio realize uma simples verifica\u00e7\u00e3o. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Voc\u00ea pode remover todo o conjunto de instrumentos para calibra\u00e7\u00e3o. (Mas n\u00e3o desmontar as partes dos nossos produtos)<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">A calibra\u00e7\u00e3o do instrumento de medi\u00e7\u00e3o e controle do n\u00edvel de l\u00edquido externo \u00e9 apresentada na figura 3.3:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"567\" height=\"485\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.3.png\" alt=\"A calibra\u00e7\u00e3o do instrumento de medi\u00e7\u00e3o e controle do n\u00edvel de l\u00edquido externo \u00e9 mostrada\" class=\"wp-image-13171\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.3.png 567w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.3-300x257.png 300w\" sizes=\"(max-width: 567px) 100vw, 567px\" \/><figcaption class=\"wp-element-caption\">Figura 3.3<\/figcaption><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>As etapas de verifica\u00e7\u00e3o s\u00e3o as seguintes:<\/strong><\/p>\n\n\n\n<ol style=\"font-size:18px\" class=\"wp-block-list\">\n<li>Preparar um tubo de \u00e1gua transparente, marc\u00e1-lo com uma escala ou corrigi-lo com uma r\u00e9gua, de modo que o n\u00edvel de l\u00edquido real pode ser observado e calibrado durante a calibra\u00e7\u00e3o. Al\u00e9m disso, preparar um amper\u00edmetro (DC) com uma precis\u00e3o de mais de tr\u00eas d\u00edgitos, v\u00e1rias rolhas de borracha, e bastante meio de teste (que pode ser substitu\u00eddo por \u00e1gua).<\/li>\n\n\n\n<li>Ligue uma extremidade do tubo de \u00e1gua transparente \u00e0 porta de fase l\u00edquida do instrumento de medi\u00e7\u00e3o e controle de n\u00edvel l\u00edquido, bloqueie a sa\u00edda de esgoto e mantenha a porta de fase gasosa desobstru\u00edda. E ligue o amper\u00edmetro em s\u00e9rie como mostrado na Figura 3.5), e depois ligue a energia ap\u00f3s confirmar que a fia\u00e7\u00e3o est\u00e1 correta.<\/li>\n\n\n\n<li>Adicione o meio da extremidade superior do tubo transparente, o meio flui atrav\u00e9s do tubo de fase l\u00edquida para o instrumento de medi\u00e7\u00e3o e controle de n\u00edvel l\u00edquido, e o n\u00edvel l\u00edquido \u00e9 adicionado a v\u00e1rios pontos com diferentes alturas, pois neste momento o n\u00edvel l\u00edquido do tubo transparente \u00e9 medido com o instrumento de medi\u00e7\u00e3o e controle de n\u00edvel l\u00edquido. O n\u00edvel de l\u00edquido no cilindro do medidor est\u00e1 exatamente em linha. Neste momento, leia o valor do amper\u00edmetro e, em seguida, compare a rela\u00e7\u00e3o de altura correspondente ao sinal padr\u00e3o de sa\u00edda 4-20mA com o valor atual coletado para verificar a precis\u00e3o do medidor de n\u00edvel (Nota: Para isso \u00e9 f\u00e1cil de calcular. Geralmente, v\u00e1rios pontos s\u00e3o tomados em 0%, 25%, 50%, 75% e 100%, respectivamente, e as correntes correspondentes s\u00e3o 4mA, 8mA, 12mA, 16mA e 20mA, respectivamente. O intervalo deve corresponder ao centro de fase l\u00edquida e fase gasosa, respectivamente).<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-3-wiring\"><strong>Instala\u00e7\u00e3o el\u00e9trica<\/strong><\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong><a href=\"https:\/\/www.kcsensor.com\/pt\/product\/capacitive-level-transmitter\/\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/product\/capacitive-level-transmitter\/\">KSLV605<\/a><\/strong> (modelo de exibi\u00e7\u00e3o) tem duas maneiras de fia\u00e7\u00e3o: um \u00e9 RS485, o outro \u00e9 <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Current_loop\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Current_loop\" target=\"_blank\" rel=\"noopener\">4\u201320 mA<\/a><\/strong>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>1: RS485<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"522\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.4.png\" alt=\"Sa\u00edda isolada de 4-20mA\" class=\"wp-image-13172\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.4.png 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.4-300x261.png 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">Figura 3.4: Sa\u00edda isolada de 4-20mA<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2: 4-20mA<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"553\" height=\"614\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.5.png\" alt=\"Sa\u00edda de 2 fios n\u00e3o isolada 4-20mA\" class=\"wp-image-13173\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.5.png 553w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/3.5-270x300.png 270w\" sizes=\"(max-width: 553px) 100vw, 553px\" \/><figcaption class=\"wp-element-caption\">Figura 3.5: Sa\u00edda de 2 fios n\u00e3o isolado 4-20mA<\/figcaption><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Ap\u00f3s a instala\u00e7\u00e3o, ao us\u00e1-la pela primeira vez, certifique-se de abrir a v\u00e1lvula de fase gasosa primeiro e, em seguida, abra a v\u00e1lvula de fase l\u00edquida para garantir que o n\u00edvel de l\u00edquido n\u00e3o ir\u00e1 flutuar violentamente, causando erros de medi\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Al\u00e9m disso, deve-se garantir que as juntas de cabo de liga\u00e7\u00e3o estejam em bom contato e anticorros\u00e3o. No uso a longo prazo, preste aten\u00e7\u00e3o \u00e0 descarga regular de esgoto, de modo a evitar o ac\u00famulo de sujeira e afetar o desempenho do instrumento. <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Tomando l\u00edquido de cobre comum, l\u00edquido de C-carbono, torre de \u00e1gua quente Baohe, piscina de esgoto e outros meios sujos como exemplo, deve ser garantida a descarga de 1 a 2 vezes por semana, enquanto o meio mais limpo deve ser descarregado 1 a 2 vezes por m\u00eas.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">O inv\u00f3lucro do transmissor deve ser firmemente enrolado para evitar a entrada de \u00e1gua, meio corrosivo ou g\u00e1s, e \u00e9 proibido colidir com for\u00e7a externa e desmont\u00e1-lo por n\u00e3o profissionais.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Existem tr\u00eas m\u00e9todos comuns de fia\u00e7\u00e3o para transmissores: como mostrado em (a) (b) (c)<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"739\" height=\"493\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/a-1.png\" alt=\"M\u00e9todos comuns de fia\u00e7\u00e3o para transmissores-1\" class=\"wp-image-13174\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/a-1.png 739w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/a-1-600x400.png 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/a-1-300x200.png 300w\" sizes=\"(max-width: 739px) 100vw, 739px\" \/><figcaption class=\"wp-element-caption\">a)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"539\" height=\"371\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/b.png\" alt=\"M\u00e9todos comuns de fia\u00e7\u00e3o para transmissores-2\" class=\"wp-image-13175\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/b.png 539w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/b-300x206.png 300w\" sizes=\"(max-width: 539px) 100vw, 539px\" \/><figcaption class=\"wp-element-caption\">b)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"443\" height=\"323\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/unnamed-file.c.png\" alt=\"M\u00e9todos comuns de fia\u00e7\u00e3o para transmissores-3\" class=\"wp-image-13176\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/unnamed-file.c.png 443w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2022\/09\/unnamed-file.c-300x219.png 300w\" sizes=\"(max-width: 443px) 100vw, 443px\" \/><figcaption class=\"wp-element-caption\">c) Am\u00edmetro<br>Figura 3.6<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-troubles-shooting\"><strong>Disparos de problemas<\/strong><\/h3>\n\n\n\n<ol style=\"font-size:18px\" class=\"wp-block-list\">\n<li>Durante a utiliza\u00e7\u00e3o, se o visor digital indicar zero, utilizar o intervalo 0-200mA do amper\u00edmetro DC, e quando a corrente medida for tamb\u00e9m 0, as poss\u00edveis falhas s\u00e3o:<br>a. A fonte de alimenta\u00e7\u00e3o 24V est\u00e1 normal?<br>b. O transmissor pode ser curto-circuito<br>c. O transmissor tem problemas de qualidade;<br>Se a corrente medida pelo amper\u00edmetro DC for inferior a 4mA, as poss\u00edveis falhas:<br>a. O n\u00edvel real de l\u00edquido est\u00e1 abaixo da porta da fase l\u00edquida<br>b. O valor de ajuste atual do transmissor \u00e9 muito baixo<br>c. O transmissor tem problemas de qualidade; se a corrente medida \u00e9 consistente com o n\u00edvel real de l\u00edquido, h\u00e1 um problema com o display digital;<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Poss\u00edveis falhas se a corrente exceder 25mA:<br>a. H\u00e1 um curto-circuito no circuito do transmissor<br>b. O valor de ajuste atual \u00e9 muito alto.<\/p>\n\n\n\n<ol start=\"2\" style=\"font-size:18px\" class=\"wp-block-list\">\n<li>Quando a tela digital estiver cheia, use o intervalo 0-200mA do am\u00f4metro DC. Quando a corrente medida \u00e9 de 20mA, pode haver uma falha:<br>a. O ajustamento actual \u00e9 demasiado elevado<br>b. H\u00e1 um curto circuito no transmissor<br>c. O n\u00edvel real de l\u00edquido est\u00e1 cheio;<br>Se a corrente medida for inferior a 20mA, o ecr\u00e3 digital \u00e9 defeituoso.<\/li>\n\n\n\n<li>O visor digital salta violentamente. Utilizando o intervalo 0-200mA do amper\u00edmetro de corrente cont\u00ednua, a corrente medida flutua demasiado e pode avariar:<br>a. Flutua\u00e7\u00e3o real do n\u00edvel l\u00edquido<br>b, m\u00e1 linha de contato<br>c. O transmissor tem problemas de qualidade; se a corrente medida \u00e9 est\u00e1vel, o medidor de exibi\u00e7\u00e3o pode ser defeituoso<\/li>\n\n\n\n<li>N\u00e3o h\u00e1 altera\u00e7\u00e3o no visor digital. Use o intervalo 0-200mA do am\u00edmetro DC. Quando a corrente medida muda normalmente, pode indicar que o instrumento \u00e9 defeituoso; se a corrente medida n\u00e3o mudar, pode ocorrer uma falha:<br>a. Falha do transmissor<br>b. O tubo de fase g\u00e1s-l\u00edquido \u00e9 bloqueado<br>c. Existe um circuito aberto entre o sensor e o transmissor e deve ser reconectado<\/li>\n\n\n\n<li>O display digital muda lentamente do que o n\u00edvel de l\u00edquido real. Ao utilizar o amper\u00edmetro 0-200mA, a corrente medida muda lentamente e pode haver uma falha:<br>a. O p\u00f3lo interno do sensor gruda nas impurezas, use \u00e1cido clor\u00eddrico 25% (\u00e1cido sulf\u00farico) para absorver o p\u00f3lo<br>b. O tubo de fase do g\u00e1s \u00e9 meio bloqueado, por favor abra a v\u00e1lvula, e teste-o, limp\u00e1-lo.<\/li>\n\n\n\n<li>Quando o display digital \u00e9 alto ou baixo, ajuste o alcance ou bot\u00e3o zero no transmissor para ajustar.<\/li>\n<\/ol>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Observa\u00e7\u00e3o: <\/strong>Para medir se h\u00e1 fonte de alimenta\u00e7\u00e3o de 24V no circuito, utilize os cabos de teste positivo e negativo do volt\u00edmetro para ligar o positivo e negativo da linha de alimenta\u00e7\u00e3o de 24V antes de medir.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Tratamento da exist\u00eancia de curto-circuito: verifique o circuito externo e o circuito transmissor e elimin\u00e1-lo<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong><a href=\"https:\/\/www.kcsensor.com\/pt\/what-is-a-capacitive-level-sensor-2\/\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/what-is-a-capacitive-level-sensor-2\/\">A Parte 1 aborda o princ\u00edpio de funcionamento, os cen\u00e1rios de aplica\u00e7\u00e3o e as vantagens do sensor;<\/a><\/strong> <\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong><a href=\"https:\/\/www.kcsensor.com\/pt\/what-is-a-capacitive-level-sensorpart-2\/\" data-type=\"link\" data-id=\"https:\/\/www.kcsensor.com\/what-is-a-capacitive-level-sensorpart-2\/\">A parte 2 fala sobre fatores de influ\u00eancia e medidas de capacit\u00e2ncia; <\/a><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>How do you use a capacitive level sensor KSLV605 Installation method 1: Gas phase and liquid phase installation Since the products are only different in appearance design and material, but both belong to the external liquid level measurement and control instrument, the installation methods of the two are basically the same, which will be explained [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":17160,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[276],"tags":[224],"class_list":["post-17150","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-capacitive-level-sensor","tag-capacitive-level-sensor"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts\/17150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/comments?post=17150"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/posts\/17150\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/media\/17160"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/media?parent=17150"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/categories?post=17150"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/pt\/wp-json\/wp\/v2\/tags?post=17150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}