{"id":20575,"date":"2026-07-03T10:33:35","date_gmt":"2026-07-03T10:33:35","guid":{"rendered":"https:\/\/www.kcsensor.com\/?p=20575"},"modified":"2026-07-08T08:59:41","modified_gmt":"2026-07-08T08:59:41","slug":"dissolved-oxygen-calibration","status":"publish","type":"post","link":"https:\/\/www.kcsensor.com\/tr\/dissolved-oxygen-calibration\/","title":{"rendered":"\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyonu \u0130\u00e7in Kapsaml\u0131 K\u0131lavuz: Do\u011fru Su Kalitesi \u00d6l\u00e7\u00fcmlerinin Sa\u011flanmas\u0131"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kcsensor.com\/tr\/category\/water-quality-monitoring-system\/do-sensor\/\" data-type=\"category\" data-id=\"277\">\u00c7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/a><\/strong>\u00a0bir \u015feyin ayarlanmas\u0131 s\u00fcrecidir <a href=\"\/tr\/category\/water-quality-monitoring-system\/do-sensor\/\" target=\"_blank\" data-type=\"category\" data-id=\"277\" rel=\"noreferrer noopener\"><strong>DO \u00f6l\u00e7er<\/strong><\/a> \u00d6l\u00e7\u00fcm sonu\u00e7lar\u0131n\u0131n sudaki veya di\u011fer s\u0131v\u0131lardaki ger\u00e7ek oksijen konsantrasyonunu do\u011fru bir \u015fekilde yans\u0131tmas\u0131n\u0131 sa\u011flamak i\u00e7in. DO \u00f6l\u00e7\u00fcm cihazlar\u0131, sens\u00f6r\u00fcn eskimesi, membran\u0131n bozulmas\u0131 veya \u00e7evresel fakt\u00f6rler nedeniyle zamanla sapma g\u00f6sterebilir. Kalibrasyon, bu de\u011fi\u015fiklikleri telafi ederek \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n hassasiyetini ve g\u00fcvenilirli\u011fini korur.<br>Ancak, en geli\u015fmi\u015f sens\u00f6rler bile d\u00fczenli olarak \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonuna ihtiya\u00e7 duyar.<br>Bu k\u0131lavuz, <strong><a href=\"\/tr\/product\/kws-600-dissolved-oxygen-sensor\/\" target=\"_blank\" data-type=\"product\" data-id=\"15337\" rel=\"noreferrer noopener\">KWS-600<\/a>,<a href=\"\/tr\/product\/fluorescence-dissolved-oxygen-sensor\/\" target=\"_blank\" data-type=\"product\" data-id=\"15476\" rel=\"noreferrer noopener\">KWS-630<\/a><\/strong>,ve <strong><a href=\"\/tr\/product\/kws-670-portable-optical-dissolved-oxygen-meter\/\" target=\"_blank\" data-type=\"product\" data-id=\"20671\" rel=\"noreferrer noopener\">KWS-670<\/a> <\/strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyon prosed\u00fcr\u00fcn\u00fc, standart \u00e7\u00f6zeltilerin haz\u0131rlanmas\u0131n\u0131 ve \u00f6nemli kullan\u0131m \u00f6nlemlerini sistematik bir \u015fekilde a\u00e7\u0131klamak amac\u0131yla \u00f6rnek olarak floresan tipi \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen sens\u00f6rleri. Daha fazla bilgi i\u00e7in \u015fu adresi ziyaret edin:\u00a0<strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Oxygen_sensor\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">burada<\/a><\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><img decoding=\"async\" width=\"150\" height=\"150\" class=\"wp-image-15340\" style=\"width: 150px;\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture.jpg\" alt=\"KWS-600 ana resmi\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture.jpg 800w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture-300x300.jpg 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture-150x150.jpg 150w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture-768x768.jpg 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture-600x600.jpg 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-600-mian-picture-100x100.jpg 100w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td><td class=\"has-text-align-center\" data-align=\"center\"><img decoding=\"async\" width=\"150\" height=\"150\" class=\"wp-image-15478\" style=\"width: 150px;\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2.jpg\" alt=\"KWS-630 Floresan \u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Sens\u00f6r\u00fc (2)\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2.jpg 800w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2-300x300.jpg 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2-150x150.jpg 150w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2-768x768.jpg 768w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2-600x600.jpg 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2024\/09\/KWS-630-Fluorescence-Dissolved-Oxygen-Sensor-2-100x100.jpg 100w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td><td class=\"has-text-align-center\" data-align=\"center\"><img data-dominant-color=\"c5d0d7\" data-has-transparency=\"false\" decoding=\"async\" width=\"150\" height=\"150\" class=\"wp-image-20669 not-transparent\" style=\"--dominant-color: #c5d0d7; width: 150px;\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67.webp\" alt=\"\" srcset=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67.webp 640w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67-300x300.webp 300w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67-150x150.webp 150w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67-600x600.webp 600w, https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/KWS-670A-67-100x100.webp 100w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"\/tr\/product\/kws-600-dissolved-oxygen-sensor\/\" target=\"_blank\" data-type=\"product\" data-id=\"15337\" rel=\"noreferrer noopener\">KWS-600<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"\/tr\/portable-dissolved-oxygen-sensors-and-analyzers\/\" target=\"_blank\" data-type=\"page\" data-id=\"21266\" rel=\"noreferrer noopener\">KWS-630<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"\/tr\/product\/kws-670-portable-optical-dissolved-oxygen-meter\/\" target=\"_blank\" data-type=\"product\" data-id=\"20671\" rel=\"noreferrer noopener\">KWS-670<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen \u00d6l\u00e7erinizi Neden Kalibre Etmelisiniz?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Do\u011fru \u00c7evresel \u0130zleme: Su organizmalar\u0131 belirli oksijen seviyelerine ba\u011fl\u0131d\u0131r; hatal\u0131 \u00f6l\u00e7\u00fcmler kirlilik veya hipoksi olaylar\u0131n\u0131 gizleyebilir.<\/li>\n\n\n\n<li>Optimize Edilmi\u015f Su \u00dcr\u00fcnleri Yeti\u015ftiricili\u011fi: Bal\u0131k ve karides yeti\u015ftiricili\u011finde, sa\u011fl\u0131kl\u0131 stoklar\u0131n korunabilmesi i\u00e7in \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen (DO) d\u00fczeyinin hassas bir \u015fekilde kontrol edilmesi gerekir.<\/li>\n\n\n\n<li>Etkili At\u0131k Su Ar\u0131t\u0131m\u0131: \u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen (DO) seviyeleri, mikrobiyal aktiviteyi ve ar\u0131tma verimlili\u011fini etkiler.<\/li>\n\n\n\n<li>Yasal Uyum: Bir\u00e7ok \u00e7evre standard\u0131, veri b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc do\u011frulamak amac\u0131yla d\u00fczenli kalibrasyon yap\u0131lmas\u0131n\u0131 zorunlu k\u0131lmaktad\u0131r.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ara\u015ft\u0131rma, operasyonlar veya mevzuata uygunlu\u011fu tehlikeye atabilecek \u00f6l\u00e7\u00fcm hatalar\u0131n\u0131 \u00f6nlemek i\u00e7in d\u00fczenli kalibrasyon \u2014ilk kullan\u0131mdan \u00f6nce, uzun s\u00fcreli depolamadan sonra ve kullan\u0131m s\u0131ras\u0131nda belirli aral\u0131klarla\u2014 hayati \u00f6nem ta\u015f\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen \u00d6l\u00e7\u00fcm\u00fcn\u00fc Anlamak<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c7\u00f6z\u00fcnm\u00fc\u015f oksijen, bir s\u0131v\u0131 i\u00e7inde \u00e7\u00f6z\u00fcnm\u00fc\u015f olan oksijen gaz\u0131n\u0131n miktar\u0131n\u0131 ifade eder ve genellikle miligram\/litre (mg\/L) cinsinden veya doygunluk y\u00fczdesi (% sat) olarak \u00f6l\u00e7\u00fcl\u00fcr. DO \u00f6l\u00e7\u00fcm cihazlar\u0131 \u015funlardan birini kullan\u0131r:\u00a0<strong>polarografik\/galvanik problar<\/strong>\u00a0veya\u00a0<strong>optik sens\u00f6rler<\/strong>\u00a0oksijen seviyelerini tespit etmek i\u00e7in.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Polarografik\/Galvanik Problar: Elektrolitle doldurulmu\u015f membranlara ihtiya\u00e7 duyan elektrokimyasal sens\u00f6rler; membran\u0131n durumuna duyarl\u0131d\u0131r.<\/li>\n\n\n\n<li>Optik Sens\u00f6rler: L\u00fcminesans s\u00f6nd\u00fcrme teknolojisini kullan\u0131r; genellikle daha kararl\u0131d\u0131r ve daha az bak\u0131m gerektirir.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Her iki sens\u00f6r t\u00fcr\u00fc de, \u00f6l\u00e7\u00fcm de\u011ferlerinin ger\u00e7ek DO konsantrasyonunu do\u011fru bir \u015fekilde yans\u0131tmas\u0131n\u0131 sa\u011flamak i\u00e7in kalibrasyona ihtiya\u00e7 duyar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyon T\u00fcrleri<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">KWS serisi sens\u00f6rler iki temel \u00f6zelli\u011fi destekler <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong> y\u00f6ntemler:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Kalibrasyon T\u00fcr\u00fc<\/strong><\/td><td><br><strong>\u00d6zellikler<\/strong><\/td><td>Ayarlanan Parametreler<\/td><\/tr><tr><td>Tek Noktal\u0131 Kalibrasyon (1 Nokta)<\/td><td>Genellikle \u015funu kullan\u0131r: <strong>100% doygunluk noktas\u0131<\/strong> referans olarak. Uygulamas\u0131 kolayd\u0131r, rutin bak\u0131m i\u00e7in uygundur.<\/td><td>Ayarl\u0131yor <strong>K de\u011feri<\/strong><\/td><\/tr><tr><td>\u0130ki Noktal\u0131 Kalibrasyon (2-Point)<\/td><td>Hem <strong>s\u0131f\u0131r noktas\u0131<\/strong> ve <strong>doyma noktas\u0131<\/strong> kalibrasyon amac\u0131yla, daha y\u00fcksek do\u011fruluk sa\u011flar. \u015eunlar i\u00e7in uygundur: <strong>yeniden kalibrasyon<\/strong> veya <strong>yeni sondalar<\/strong>.<\/td><td>Ayarl\u0131yor <strong>K de\u011feri<\/strong> ve <strong>B de\u011feri<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>K e\u011fimi, B ise s\u0131f\u0131r kaymas\u0131n\u0131 temsil eder.<\/em><br>Farkl\u0131 <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong> Uygulama gereksinimlerine g\u00f6re farkl\u0131 tipler se\u00e7ilebilir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyonu i\u00e7in Standart \u00c7\u00f6zeltilerin Haz\u0131rlanmas\u0131<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. <strong>S\u0131f\u0131r Noktas\u0131 Standart \u00c7\u00f6zeltisi<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u0131f\u0131r kalibrasyonu, oksijensiz bir ortamda probun \u00e7\u0131k\u0131\u015f de\u011ferini belirler.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Haz\u0131rl\u0131k a\u015famalar\u0131:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Bir beher kab\u0131na 95\u2013200 mL dam\u0131t\u0131lm\u0131\u015f veya deiyonize su ekleyin.<\/li>\n\n\n\n<li>Yakla\u015f\u0131k 5 g susuz sodyum s\u00fclfit (Na\u2082SO\u2083) ekleyin.<\/li>\n\n\n\n<li>~5% sodyum s\u00fclfit \u00e7\u00f6zeltisi elde etmek i\u00e7in, tamamen \u00e7\u00f6z\u00fcnene kadar bir cam \u00e7ubukla kar\u0131\u015ft\u0131r\u0131n.<\/li>\n\n\n\n<li>\u00c7\u00f6z\u00fcnmemi\u015f kristaller kal\u0131rsa, \u00e7\u00f6zelti doymu\u015f demektir ve kullan\u0131ma haz\u0131rd\u0131r.<\/li>\n\n\n\n<li>Bu \u00e7\u00f6zelti, \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijeni h\u0131zla emerek neredeyse 0 mg\/L seviyesine ula\u015f\u0131r ve \u015fu ama\u00e7larla kullan\u0131l\u0131r: <strong>s\u0131f\u0131r noktas\u0131 \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong>.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">2. <strong>100% Oksijenle Doymu\u015f Ortam<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u015eu ama\u00e7larla kullan\u0131l\u0131r: <strong>e\u011fim (ger\u00e7ek \u00f6l\u00e7ekli)<\/strong> kalibrasyon.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> <strong>Y\u00f6ntem 1: Hava ile Doyurulmu\u015f Su (\u00d6nerilen)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Termostatik su banyosunun yakla\u015f\u0131k \u00fc\u00e7te ikisini taze dam\u0131t\u0131lm\u0131\u015f suyla doldurun.<\/li>\n\n\n\n<li>K\u00fc\u00e7\u00fck bir hava pompas\u0131 kullanarak en az bir saat boyunca s\u00fcrekli havaland\u0131r\u0131n.<\/li>\n\n\n\n<li>Hava ile doygun su elde etmek i\u00e7in yakla\u015f\u0131k 20 dakika bekletin.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"> <strong>Y\u00f6ntem 2: Nemli Hava Y\u00f6ntemi (Basitle\u015ftirilmi\u015f Yerinde Uygulama S\u00fcr\u00fcm\u00fc)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sens\u00f6r\u00fcn optik membran\u0131n\u0131 temizleyin.\u3001<br>Prob'u nemli bir ortama yerle\u015ftirin (\u00f6rne\u011fin, i\u00e7inde az miktarda su bulunan kapal\u0131 bir kaba).<br>De\u011fer sabitlendi\u011finde, tam \u00f6l\u00e7ek \u00f6l\u00e7\u00fcm\u00fcn\u00fc ger\u00e7ekle\u015ftirin <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong>.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyon Prosed\u00fcr\u00fc<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"> <strong>1. S\u0131f\u0131r Noktas\u0131 Kalibrasyonu<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Prob'u \u015furaya yerle\u015ftirin: <strong>5% sodyum s\u00fclfit \u00e7\u00f6zeltisi<\/strong>.<\/li>\n\n\n\n<li>Membran ba\u015fl\u0131\u011f\u0131n\u0131n <strong>tamamen suya batm\u0131\u015f<\/strong> ve <strong>hava kabarc\u0131\u011f\u0131 i\u00e7ermeyen<\/strong>.<\/li>\n\n\n\n<li>\u015eunun k\u0131saltmas\u0131 olsun <strong>yakla\u015f\u0131k 3 dakika<\/strong> okuma de\u011feri sabitlenene kadar.<\/li>\n\n\n\n<li>\u015eunu \u00e7al\u0131\u015ft\u0131r\u0131n: <strong>\u201c\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Seviyesi S\u0131f\u0131r Olarak Ayarlama\u201d<\/strong> cihaz \u00fczerindeki komutla veya \u00fcst bilgisayar yaz\u0131l\u0131m\u0131 arac\u0131l\u0131\u011f\u0131yla.<\/li>\n\n\n\n<li><strong>Kaydet<\/strong> ayarlar.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Tam \u00d6l\u00e7ekli (E\u011fim) Kalibrasyonu<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Probu \u015furaya yerle\u015ftirin <strong>hava ile doymu\u015f su<\/strong> (ya da bir <strong>nemli hava ortam\u0131<\/strong>).<\/li>\n\n\n\n<li>\u015eunun k\u0131saltmas\u0131 olsun <strong>yakla\u015f\u0131k 3 dakika<\/strong> okuma de\u011feri sabitlenene kadar.<\/li>\n\n\n\n<li>\u015eunu \u00e7al\u0131\u015ft\u0131r\u0131n: <strong>\u201cE\u011fim Bazl\u0131 \u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyonu\u201d<\/strong> komut ve <strong>kaydet<\/strong> ayarlar.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. \u0130ki Noktal\u0131 (K ve B De\u011feri) Manuel Kalibrasyon (\u00d6rnek: KWS-630)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kalibrasyon parametrelerinin manuel olarak hesaplanmas\u0131 gerekti\u011finde, a\u015fa\u011f\u0131daki ad\u0131mlar\u0131 izleyin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Varsay\u0131lan ayarlara s\u0131f\u0131rla: K = 1, B = 0.<\/li>\n\n\n\n<li>100% oksijen ortam\u0131nda Y de\u011ferini \u00f6l\u00e7\u00fcn (\u00f6rn., Y = 0,96).<\/li>\n\n\n\n<li>S\u0131f\u0131r \u00e7\u00f6zeltisinde X de\u011ferini \u00f6l\u00e7\u00fcn (\u00f6rn., X = 0,015).<\/li>\n\n\n\n<li>Hesapla: \u00d6rnek: K \u2248 1,05, B \u2248 -0,016.<\/li>\n\n\n\n<li>MODBUS komutu arac\u0131l\u0131\u011f\u0131yla parametreleri sens\u00f6re yaz\u0131n. Bu i\u015flemle <strong>iki noktal\u0131 \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong>.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Hesaplama:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"f8f8f8\" data-has-transparency=\"false\" style=\"--dominant-color: #f8f8f8;\" loading=\"lazy\" decoding=\"async\" width=\"265\" height=\"67\" src=\"https:\/\/www.kcsensor.com\/wp-content\/uploads\/2025\/10\/\u56fe\u72471.webp\" alt=\"\" class=\"wp-image-20600 not-transparent\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">(\u00d6rnek sonu\u00e7: K \u2248 1,05, B \u2248 \u20130,016)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hesaplanan parametreleri elde ettikten sonra,<strong>de\u011ferleri (K ve B) yaz\u0131n<\/strong> sens\u00f6re \u015fu yolla <strong>MODBUS komutu<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyonu \u0130\u00e7in Gerekli Malzemeler ve Ekipmanlar<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u0130sim<\/td><td>A\u00e7\u0131klama<\/td><\/tr><tr><td>Susuz Sodyum S\u00fclfit (Na\u2082SO\u2083)<\/td><td>S\u0131f\u0131r noktas\u0131 (oksijensiz) kalibrasyon \u00e7\u00f6zeltisini haz\u0131rlamak i\u00e7in kullan\u0131l\u0131r<\/td><\/tr><tr><td>Dam\u0131t\u0131lm\u0131\u015f \/ \u0130yonu Giderilmi\u015f Su<\/td><td>Kalibrasyon ortam\u0131 ve \u00e7\u00f6zelti haz\u0131rlama i\u00e7in \u00e7\u00f6z\u00fcc\u00fc<\/td><\/tr><tr><td>Beher ve Cam Kar\u0131\u015ft\u0131rma \u00c7ubu\u011fu<\/td><td>Kalibrasyon \u00e7\u00f6zeltilerinin haz\u0131rlanmas\u0131 ve kar\u0131\u015ft\u0131r\u0131lmas\u0131 i\u00e7in<\/td><\/tr><tr><td>K\u00fc\u00e7\u00fck Hava Pompas\u0131 \/ Havaland\u0131r\u0131c\u0131<\/td><td>Suyu havaland\u0131rmak ve hava ile doyurulmu\u015f (100%) \u00e7\u00f6zelti elde etmek i\u00e7in kullan\u0131l\u0131r<\/td><\/tr><tr><td>Eldivenler, \u00d6l\u00e7\u00fc Silindiri, Terazi<\/td><td>Laboratuvarda g\u00fcvenli \u00e7al\u0131\u015fmay\u0131 ve do\u011fru \u00f6l\u00e7\u00fcmleri sa\u011flay\u0131n<\/td><\/tr><tr><td>Termostatik Su Banyosu (\u0130ste\u011fe Ba\u011fl\u0131)<\/td><td>Kalibrasyon s\u0131ras\u0131nda hava ile doyurulmu\u015f suyun s\u0131cakl\u0131\u011f\u0131n\u0131 kontrol eder<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bu bile\u015fenler bir araya gelerek eksiksiz bir <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyon d\u00fczene\u011fi<\/strong>, kalibrasyon do\u011frulu\u011funu ve tekrarlanabilirli\u011fini garanti eder.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00c7\u00f6z\u00fcnm\u00fc\u015f Oksijen Kalibrasyonu S\u0131ras\u0131nda Al\u0131nmas\u0131 Gereken \u00d6nlemler<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\u00dcr\u00fcn<\/td><td>\u00d6nemli Noktalar<\/td><\/tr><tr><td>Temizlik ve Kabarc\u0131k \u00d6nleme<\/td><td>Hava kabarc\u0131klar\u0131n\u0131n yap\u0131\u015fmas\u0131n\u0131 \u00f6nlemek i\u00e7in kalibrasyondan \u00f6nce probun membran y\u00fczeyini iyice temizleyin.<\/td><\/tr><tr><td>S\u0131cakl\u0131k Dengeleme<\/td><td>D\u00f6n\u00fc\u015f\u00fcm hatalar\u0131n\u0131 \u00f6nlemek i\u00e7in s\u0131cakl\u0131k sens\u00f6r\u00fcn\u00fcn d\u00fczg\u00fcn \u00e7al\u0131\u015ft\u0131\u011f\u0131ndan emin olun.<\/td><\/tr><tr><td>Stabilizasyon S\u00fcresi<\/td><td>Devam etmeden \u00f6nce, her bir kalibrasyon noktas\u0131n\u0131n okunan de\u011fer tamamen sabit hale gelene kadar en az 3 dakika bekletilmesini sa\u011flay\u0131n.<\/td><\/tr><tr><td>\u00c7evresel Ko\u015fullar<\/td><td>Kalibrasyon do\u011frulu\u011funu etkileyebilecek g\u00fc\u00e7l\u00fc \u0131\u015f\u0131k, manyetik parazit ve titre\u015fimlerden ka\u00e7\u0131n\u0131n.<\/td><\/tr><tr><td>\u00c7\u00f6zeltinin Tazeli\u011fi<\/td><td>Oksijen konsantrasyonundaki sapmay\u0131 \u00f6nlemek i\u00e7in, oksijensiz \u00e7\u00f6zelti ve hava ile doyurulmu\u015f su her seferinde taze olarak haz\u0131rlanmal\u0131d\u0131r.<\/td><\/tr><tr><td>Veri Kayd\u0131<\/td><td>\u0130zlenebilirlik ve kalite kontrol\u00fc amac\u0131yla kalibrasyon s\u00fcresini, operat\u00f6r\u00fc ve parametre de\u011ferlerini kaydedin.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bu uygulamalar\u0131 takip etmek, sisteminizin g\u00fcvenilirli\u011fini ve tutarl\u0131l\u0131\u011f\u0131n\u0131 \u00f6nemli \u00f6l\u00e7\u00fcde art\u0131racakt\u0131r. <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sonu\u00e7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130ster <a href=\"https:\/\/www.kcsensor.com\/tr\/product\/kws-600-dissolved-oxygen-sensor\/\" data-type=\"product\" data-id=\"15337\">K<\/a><a href=\"\/tr\/portable-dissolved-oxygen-sensors-and-analyzers\/\" target=\"_blank\" data-type=\"page\" data-id=\"21266\" rel=\"noreferrer noopener\">WS-600<\/a>,<a href=\"\/tr\/product\/fluorescence-dissolved-oxygen-sensor\/\" target=\"_blank\" data-type=\"product\" data-id=\"15476\" rel=\"noreferrer noopener\">KWS-630<\/a>, ve <a href=\"\/tr\/product\/kws-670-portable-optical-dissolved-oxygen-meter\/\" target=\"_blank\" data-type=\"product\" data-id=\"20671\" rel=\"noreferrer noopener\">KWS-670<\/a> serisinde, floresan tipi \u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen sens\u00f6rlerinin hassasiyeti nihayetinde do\u011fru <strong>\u00e7\u00f6z\u00fcnm\u00fc\u015f oksijen kalibrasyonu<\/strong> ve bak\u0131m.<br>Standart \u00e7\u00f6zeltilerin haz\u0131rlanmas\u0131n\u0131 iyi \u00f6\u011frenerek, K\/B parametrelerinin \u00f6nemini kavrayarak ve standart prosed\u00fcrleri uygulayarak, sens\u00f6r\u00fcn\u00fcz\u00fcn en iyi performans\u0131 sergilemesini sa\u011flayabilir ve su kalitesi izleme i\u00e7in do\u011fru ve istikrarl\u0131 veriler elde edebilirsiniz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Dissolved oxygen calibration\u00a0is the process of adjusting a DO meter to ensure its readings accurately reflect the true oxygen concentration in water or other liquids. DO meters can drift over time due to sensor aging, membrane degradation, or environmental factors. Calibration compensates for these changes, maintaining the meter\u2019s precision and reliability.However, even the most advanced [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":21679,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[113,209,277,212],"tags":[],"class_list":["post-20575","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dissolved-oxygen-sensor","category-dissolved-oxygen-probe","category-do-sensor","category-water-quality-monitoring-system"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/posts\/20575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/comments?post=20575"}],"version-history":[{"count":0,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/posts\/20575\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/media\/21679"}],"wp:attachment":[{"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/media?parent=20575"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/categories?post=20575"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kcsensor.com\/tr\/wp-json\/wp\/v2\/tags?post=20575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}