Why Choose TDLAS200 Laser Methane Gas Sensor?

Product modelTDLAS200A(Pump)TDLAS200B(Diffusion)
PictureTDLAS200 Laser Methane Sensor-200X200TDLAS200B Laser Methane Sensor-200X200
Detection objectMethane (CH4)
Measurement principleLaser absorption spectrum (TDLAS)
Static detection limit0.5ppm@25℃ 5SPS (typical value, please contact us for details)
Volume53ml
Fastest response time0.2s90s
Measurement range0~5000ppm,0-10000ppm
Measurement deviation0–200 ppm: ±2 ppm of the true value
200–1000 ppm: ±1% of the true value
1000–5000 ppm: ±2% of the true value
5000–10000 ppm: ±3% of the true value
12hrs drift+/-1.5ppm
Operating temperature-20~50℃
Power supply5-12VDC 1W (typical) 6W (maximum)
Recommended 12V 1A
Dimensions115×59×38mm115×59×40mm
Gas inlet/outlet portPagoda direct M-5AU-4None
*1 Please ensure that the power input voltage of the module is not less than 5V

*2 Pump selection recommendation <500ml/min

Application

Industrial Value