1. Project Background
A textile dyeing and finishing plant in Suzhou, Jiangsu Province treats wastewater containing high concentrations of organic compounds. To comply with increasingly strict environmental regulations, the plant needed continuous online monitoring of chemical oxygen demand (COD) to ensure treated water met discharge standards.

Traditional laboratory testing was time-consuming and could not provide real-time feedback. The plant introduced the KWS-100 Online COD Sensor to monitor COD levels continuously and integrate with the plant’s automated control system for dynamic wastewater treatment adjustments.
2. Wastewater Characteristics and Monitoring Requirements
The plant’s wastewater has significant COD variability due to the use of dyes, chemical additives, and solvents during production. Monitoring requirements included:
- High variability in COD concentration
- Real-time monitoring to allow timely adjustment of coagulant and oxidizing agents
- Compliance with discharge regulations: COD <100 mg/L for treated water
The KWS-100 sensor was selected to provide real-time feedback on COD fluctuations, optimize treatment efficiency, and reduce chemical overuse.
3. System Configuration and Installation
The KWS-100 sensor was installed on the main inlet pipe of the wastewater treatment system:
- KWS-100 Online COD Sensor
- Range: 0–1000 mg/L
- Output: RS485 (Modbus RTU)
- Installation: Immersion type, ensuring stable contact with flow and easy maintenance
- Housing Material: 316L stainless steel, resistant to industrial corrosion
- Automatic Cleaning: Reduces fouling, maintains measurement stability
- Integration:
RS485 output connected to the plant PLC system for continuous monitoring, trending, and process feedback.

You want to know:
How to use the KWS-100 COD Sensor?
How to calibrate the KWS-100 COD Sensor?
4. Operational Performance
Since deployment, the KWS-100 sensor has provided reliable online data:
- Normal operation COD: 60–80 mg/L
- Peak COD during high production: 120–150 mg/L
- Rapid response to COD spikes allowed timely adjustment of chemical dosing
- After 8 months of operation, statistical analysis shows over 95% of COD measurements remain below 100 mg/L, confirming stable wastewater quality and reliable sensor performance
5. Project Summary
The KWS-100 Online COD Sensor enabled the plant to continuously monitor COD levels and optimize wastewater treatment. Its 316L stainless steel housing, RS485 output, and automatic cleaning function ensure long-term stability, reduced maintenance, and compliance with environmental regulations.
For more technical details, wiring diagrams, or model selection guidance, please click here to learn more or contact our technical team.