1. Product Introduction
1.1 What Is the KUS3000 Series Ultrasonic Sensor?
The KUS3000 series ultrasonic sensor is a sensor developed by KACISE for industrial automation applications. It features faster response speed and more flexible installation options.
The sensor housing is fully threaded, with a nickel-plated brass housing as standard, offering strong anti-interference performance. Other housing materials can be customized, such as PTFE corrosion-resistant housings.
The maximum measuring distance covers 1 m to 15 m. The product lineup includes KUS3000-M18, KUS3000-M30-Type1, KUS3000-M18-Type2, and KUS3000-M18-Type3.
The KUS3000 series supports NPN and PNP switching outputs, 4–20 mA and 0–10 V analog outputs, and RS485 Modbus communication. It is suitable for various industrial measurement scenarios. RS485 can be integrated with a 4G module to enable real-time monitoring of measurement values.

1.2 Advantages of the KUS3000 Series Ultrasonic Sensor
- Non-contact measurement, no contact with the measured medium
- High accuracy, up to 0.5%
- Optional voltage output
- Fast response speed
2. KUS3000 Series Ultrasonic Sensor Parameter Comparison
| Model | KUS3000-M18 | KUS3000-M30-Type1 | KUS3000-M30-Type2 | KUS3000-M30-Type3 |
| Measuring Distance | 1m | 2m | 4m | 6.5m / 15m |
| Blind Zone | 0.15m (small blind zone optional) | 0.2m | 0.3m | 0.4m / 0.6m |
| Accuracy | ≤ 0.5%–1% FS | |||
| Installation | M18×1 | M30×1.5 | ||
| Power Supply | 3.3–30 VDC (RS485) 12–30 VDC (switch and analog output) | |||
| Protection Rating | IP65 | |||
| Output Signal | NPN / PNP / 0–10 V / 4–20 mA / RS485 Modbus / 4–20 mA + RS485 | |||
| Temperature Compensation | All sensors are equipped with temperature compensation | |||
| Operating Temperature | -25 to 70 °C | |||
| Storage Temperature | -40 to 85 °C | |||
| Housing Material | Nickel-plated brass housing (PTFE customizable) | |||
3. Explanation of Core Selection Parameters
| Parameter | Description |
| Measuring Distance | The maximum distance that the sensor can measure |
| Blind Zone | The distance from the sensor face within which measurement is ineffective |
| Protection Rating | Indicates the device’s resistance to dust, water, and foreign object intrusion |
| Output Signal | The output form of the sensor. PNP and NPN are switching outputs commonly used for industrial control; 4–20 mA is an analog output for process monitoring; RS485 can be understood as the digital output of the sensor |
| Temperature Compensation | Changes in ambient temperature affect the speed of sound and can cause measurement errors, therefore temperature compensation is required |
4. Step-by-Step Selection Process
Step 1: Determine the Measuring Range
- Identify the maximum measuring range required in the application environment
- Select a model that fully covers the maximum depth
Step 2: Determine Required Outputs
- Confirm the communication protocol or signal type (e.g., RS485 interface, 4–20 mA analog output)
Step 3: Consider Environmental Conditions
- Identify the operating environment (e.g., corrosive environment, outdoor environment, temperature, pressure)
- Determine accuracy requirements, protection rating, and housing material
Step 4: Evaluate Installation Compatibility
- Download the product manual
- Confirm the installation method based on product dimensions and thread specifications
Step 5: Consult Professionals
- If you are still unsure about the selection, consult the KACISE professional technical team, who will provide more targeted recommendations based on your specific requirements and on-site conditions
5. Typical Application Scenarios
| Application | Recommended Model | Reason |
| Small Liquid Storage Tanks (Tank depth < 1 m) | KUS3000-M18 | Compact size, easy installation. Supports switching output and can work with pumps to control filling and draining processes. |
| Industrial Production Line Counting | KUS3000-M30-Type1 | Maintains a certain distance to monitor products on the production line from above. Product present → distance shortens → switch triggered → counting achieved. |
| Long-Distance Production Line Detection | KUS3000-M30-Type3 | Larger measuring range allows detection of product presence on long production lines. If no product is detected, the switch output can be triggered for alarm purposes. |
6. Summary
To help you quickly identify the appropriate KUS3000 series ultrasonic level sensor, this article provides a detailed explanation of product parameter differences, core parameter definitions, step-by-step selection procedures, and typical application scenarios, enabling you to quickly find the most suitable model.
If you still have selection questions or need customized solutions based on specific measurement requirements, please feel free to contact us directly. Our professional team will provide one-on-one guidance to help you select the most cost-effective level sensor.