KGF125 Gear Flow Meter
Introduction
Gear Flow Meter belongs to a kind of volumetric flow transmitter and can be us ed for measuring volume and flow precisely. The flowing medium makes the gear engage and rotate. Under the flowing effect of fluid, pressure difference is formed between the inlet and outlet of instrument. One pair of gears can rotate freely without the need of power supply. The empty cavity between gears is filled with liquid, which is discharged through rotation. The liquid flowing through instrument and liquid flow can be known through measuring the number of revolutions of gear.
principle
The rotation speed of the transmitter is detected by the sensing coil inside the signal amplifier on the case. The signal amplifier cannot contact the measured medium. The magnetic line of force generated inside the permanent magnet inside the case due to transmitter gear cutting will lead to flux change inside the sensing coil. The sensing coil sends the signal of flux change cycle detected to the pre-amplifier to amplify and shape the signal. The impulse signal which is in direct ratio with flow velocity will be sent to the unit conversion and flow integration circuit to obtain and display the accumulative flow valve. At the same time, it will also send the impulse signal to frequency current conversion circuit to convert the impulse signal to simulation amperage to display the instantaneous flow value.
The Gear Flow Meter has high processing precision and can be installed precisely. The gear rotation undergoes non-contact scanning. One impulse is generated by one gear with very high resolution. The column gear transmission can measure the liquid with very small flow and small quantitative volume.
Application
- Measurement of resin and glue
- Measurement of hydraulic oil, lubricating oil and grease
- Measurement of fuel oil
- Measurement of printing ink and asphalt
- Measurement of liquid nitrogen, refrigerant, and solvent
- Measurement of edible oil, fish oil and food canning
- Fluid quantitative control system
Features
- Support pulse, 4-20ma and RS485 output
- High voltage resistance (1.0-45MPa)
- High and low temperature resistance (-196℃-170℃)
- Able to measure different kinds of viscous media.
- High precision and repeatability
- Range ratio width (1: 100)
- Broad range of measurement
- Strong corrosion and pollutant resistance (acid and alkaline)
Dimension
Unit: mm
| Model | A | B | C | D | E | F | G |
| KGF102 | Φ83 | 80 | 50 | 70 | G1/4 | 40 | M6 |
| KGF104 | Φ83 | 80 | 50 | 70 | G1/4 | 55 | M6 |
| KGF106 | Φ83 | 80 | 62 | 70 | G1/2 | 55 | M6 |
| KGF110 | Φ83 | 80 | 62 | 70 | G1/2 | 55 | M6 |
| KGF115 | Φ113 | 110 | 62 | 70 | G3/4 | 90 | ,M6 |
| KGF125 | Φ158 | 140 | 85 | 70 | G1 | 110 | M8 |
| KGF132 | Φ218 | 160 | 100 | 70 | M35*1.5 | 180 | M8 |
The sizes are above are for the standard products. Customization is acceptable.
| Model | Range(L/H) | K Coeff(P/L) | Interface | Pipe Size | Accuracy |
|---|---|---|---|---|---|
| KGF102 | 0.6-50 | 11200 | G1/4 | DN6 | +/- 0.5%(Range:1: 10) +/- 1.0%(Range: 1:100) |
| KGF104 | 5-250 | 4780 | G3/8 | DN10 | |
| KGF106 | 10-500 | 3468 | G1/2 | DN15 | |
| KGF110 | 50-1200 | 2780 | G1/2 | DN15 | |
| KGF115 | 200-3000 | 334 | G3/4 | DN20 | |
| KGF125 | 1000-12000 | 59.9 | G1 | DN25 | |
| KGF132 | 2000-20000 | 39.9 | G1-1/4 | DN32 |