KUFS2000C Explosion-Proof Clamp On type Ultrasonic Flow Meter

Introduction

The KUFS2000C flow meter adopts isolated explosion proof, grade DΙΙBT5 . Clamp on sensors are installed on the pipe. After gluing and sealing, grade will be Intrinsically safe explosion. Suitable for pipe sizes from DN32mm to DN6000mm.

Dimensions

KUFS2000C Flow Meter Dimension 1

Standard Clamp On Sensor

Standard Clamp On Sensor 500X500

  • Built-in magnet, easy to be absorbed on pipe
  • IP68
  • Measuring range: DN32~DN6000
  • Temperature range: – 30~90℃
Type Model Measuring Range Temperature Dimension
Small Size TS-2 DN32~DN100 – 30~90℃ 45×25×28mm
Middle Size TM-1 DN50~DN700 – 30~90℃ 64×39×44mm
Large Size TL-1 DN300~DN6000 – 30~90℃ 97×54×53mm

High Temperature Clamp On Sensor

High Temperature Clamp On Sensor 500X500

  • Built-in magnet, easy to be absorbed on pipe
  • IP68
  • Measuring range: DN32~DN6000
  • Temperature range: – 30~160℃
Type Model Measuring Range Temperature Dimension
Small Size TS-2-HT DN32~DN100 – 30~160℃ 45×25×28mm
Middle Size TM-1-HT DN50~DN700 – 30~160℃ 64×39×44mm
Large Size TL-1-HT DN300~DN6000 – 30~160℃ 97×54×53mm

Mounting Bracket Clamp On Sensor

Mounting Bracket Clamp On Sensor 500X500

  • Improve installation efficiency and accuracy
  • IP68
  • Measuring range: DN32~DN700
  • Temperature range: – 30~160℃
Type Model Measuring Range Temperature Dimension
Standard Small Size Sensor HS DN32~DN100 – 40~90℃ 318×59×85mm
Standard Middle Size Sensor HM DN50~DN300 – 40~90℃ 568×59×85mm
Extended (bracket only) EB-1 >DN300 – 40~90℃ 88×59×49mm
High Temp. Small Size Sensor HS-HT DN32~DN100 – 40~160℃ 318×59×145mm
High Temp. Middle Size Sensor HM-HT DN50~DN300 – 40~160℃ 568×59×145mm
Extended (bracket only) EB-1-HT >DN300 – 40~160℃ 88×59×49mm

Ordering Information

KUF2000 Series Ordering Information

ParameterParameter
Working ConditionMain UnitSensor
ProtectionIP65IP68
Humidity≤85%RH
Temperature-20~60℃-30~160℃
Basic Parameters
Accuracy≤1%
Velocity Range0~±10m/s, Bi-directional measurement
Pipe SizeDN32~DN6000
Temperature- 30~160℃
Type of LiquidSingle liquid can transmit sound wave. such as water, sea water, sewage, oil, chemicals , alcohol, etc
Pipe MaterialSteel, Stainless steel, Cast iron, Copper, PVC, Aluminum, Glass steel, etc. Liner is allowed
Signal Output1 way 4-20mA output(impedance 0~1K, accuracy 0.1%)
1 way OCT pulse output( Pulse width 6 ~ 1000ms)
1 way relay output
Signal Input3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor.
InterfaceRS485, support MODBUS
Data StorageSD card regularly store the pre-set results (optional)
Power SupplyDC8~36V or AC85~264V
Clamp On type Ultrasonic Flow Meter installation

Customer Reviews

Write or update your review


Already reviewed this product? Submitting again adds your new text and photos to your existing review — your original rating is kept.




First review: please write at least 10 characters. Adding to an existing review: a photo alone is fine.


Contact Us


Scroll to Top

Your inquiry will be responseed in 12 hours .
For any urgent case, you can contact us via whatsapp or phone.

whatsapp
Tel
thank-you