Customer Feedback
“Reliable performance in satellite IoT communication.”
— Industrial Client
Customer Feedback
“Reliable performance in long-term satellite IoT deployment.”
— Ally

KOCF3000A Ultrasonic Open Channel Flow Meter – Integrated type

Instruction

The KOCF3000A ultrasonic open channel flow meter, together with measuring weir flume, is used to measure water flow in open channel. It is mainly used to measure the flow of sewage plant, sewage discharge outlet of enterprises and public institutions, urban sewers, as well as the channels for irrigation and water conservancy.

Feature

As for the meters produced by KACISE, the non-contact method is used for measurement by letting ultrasonic wave passing through air. Therefore, they are more reliable and durable in dirty and corrosive solutions compared with the contact-type meters.

Dimension

 

KCOF3000A KOCF3000B Ultrasonic Open Channel Flow Meter Dimension

FunctionsIntegrated type
Measurement range0.1L/s~99999.99m3/h, according to flume
Total flowMax.: 4290000000.00m3
Max. scale value of water level1m, 2m, 5m, 10m. customizable
Accuracy of water level0.5%
Resolution ratio3mm or 0.1%
DisplayLCD display
Flow measurement accuracy1~5% for standard Parshall flume and triangular weir
10% for standard rectangular weir
10~50% for non-standard weir and flume
Analog output4-wire, load of 4~20mA/510Ω
Relay output(Optional) 2 AC 250V/(NO:10A, NC:6A)
or DC 24V/10A, state programmable
Power supplyStandard 24VDC 0.1A; or optional 220V AC+15% 50Hz
Power supply(Optional) 12VDC, supplied by battery or solar energy
Working temperaturedisplay instrument -20~+60°C, probe -20~+80°C
Working pressureStandard atmospheric pressure
Working temperature≤90%RH, non-condensed
Process temperature-20~+80℃
Process pressureStandard atmospheric pressure
CommunicationOptional, 485 & 232 communication, MODBUS protocol
IP gradeMeter IP66, probe IP68
Probe cableNone
Probe selectionIt is recommended to use a 100KHz M48×2 probe for No. 1-5 Parshall trough, with a measuring range of 2 meters (the length of the sensor line is less than 12 meters). The probe is not easy to hit the wall or corner of the Parshall trough to form false signals.
The blind area of the M48×2 probe is small, only 13-15 cm, and the mounting bracket can be made even lower.
It is recommended to use a 64Khz M48×2 probe for No. 6-25 Parshall trough, with a measuring range of 3 meters and a blind area of 30-40 cm.
Probe materialStandard made by ABS, and anticorrosive material shall be used for ones for the corrosive environment
Power dissipation of split type24V split type, the power is as follows:
Only with mA output is 1.5W (standard configuration);
Only with 485 output is 0.9W (optional);
Simultaneously with 485 and mA output is 1.6W (optional);
Adding two relays increases the power consumption by 0.8W on the original basis;

220VAC split type power is 5W.
Power dissipation of integrated type24V integrated four-wire model, the power is as follows:
Only with mA output is 1W (standard configuration);
Only with 485 output is 0.6W (optional);
Simultaneously with 485 and mA output is 1.05W (optional);
Add two relays, the power consumption is increased by 1W on the original basis;

The 220VAC integrated four-wire model has a power of 5W.